The Procedure of Fabricating for MS2500 

1.  Put the four adjustable feet into each of hole which rear of 

platform.   
See figure 1. 

 

Figure 1 

2.  Screw two stainless steel sticks into two sides of platform.  

See figure 2. 

 

 

Figure 2

 

D I S P L A Y   S Y M B O L S  

Symbol Description 

  

scale in auto zero range    (indication = accurate zero) 

 

result is stable   

kg , lb or oz 

scale in weighing mode 

Lo-bAt 

Battery is weak, after 5 minutes the scale will turn off   

 

Show the Net Weight is being display (NW) or the 

Gross Weight is displayed (GW) 

 

 

CALIBRATION

 

 

Occasionally the scale should be verified that it is weighing correctly 
by measuring a known mass of approximately the scale capacity.     
Tare the scale, place the mass on the center of the platform and 
note the reading.    Calibrate the scale if necessary. 

Before beginning make sure you have the mass specified and you 
know the mass is accurate.   

 

PROCEDURE 

Turn the scale off. 
Press and hold the 

On/Zero/Off

 key then press the 

Units

 key 3 

times. Release the 

ON/Zero/OFF

 key. The display will show the 

gravity value of the factory—9.789.    Press the 

Tare

 key to move 

to the desired digit, and press the 

Units 

key to set the gravity of 

destination.  Then press the 

Tare 

key to confirm the entered 

gravity.    Display will show zero. 
Place the calibration weight (below) on the scale, centered on the 

platform. 

MS2500   300kg 

mass 

Press the 

Tare

 key again. 

The display will show " CAL" then return to weighing showing the 
value of the weight used.     
Remove the weight.    Verify the scale is calibrated correctly. 

Содержание MS-2500

Страница 1: ...tured in accordance with the harmonised European standards following the provisions of the below stated directives Electro Magnetic Compatibility Directive 89 336 EEC Low Voltage Directive 73 23 EEC Marsden Group Holding Ltd WM 25 TARE ZERO HOLD UNIT OFF ON USER S MANUAL ...

Страница 2: ... DC adaptor for operations and recharge DC ADAPTOR OPERATION Note Always fit the Adaptor to the scale BEFORE connecting to an electrical outlet Disconnect from the electrical outlet BEFORE disconnecting the adaptor from the scale SPECIFICATIONS Model MS 2500 Maximum Capacity 300 kg 660 lb Separation division 100 g 0 2 lb Weight unit Kg Lb oz Power Supply Rechargeable battery pack 15V 300mA DC adap...

Страница 3: ...ght Press HOLD or TARE button to disable HOLD function Turn the scale on using the On Zero Off key After the display is at zero place an item to be weighed on the platform The display will show the weight The unit will be shown in kilograms unless the user has selected either pounds or ounces previously If an empty container is used the weight can be ignored by zeroing the display To zero the disp...

Страница 4: ...7 ...

Страница 5: ...e capacity Tare the scale place the mass on the center of the platform and note the reading Calibrate the scale if necessary Before beginning make sure you have the mass specified and you know the mass is accurate PROCEDURE Turn the scale off Press and hold the On Zero Off key then press the Units key 3 times Release the ON Zero OFF key The display will show the gravity value of the factory 9 789 ...

Страница 6: ...ng unit can be enabled or disabled 4 The Automatic Turn off time can be set or disabled off Each BMI can be enabled or disabled 5 SEt kg Lb Oz Unit 120 180 240 300 Off A Off On Off On Off St On Off On Off Unit A off CAP CAL DIV GRAV BMI On Off The other functions do not apply to the users Advance to END in order to exit the menu If you need use BMI be sure that you set BMI on and go to END first P...

Страница 7: ...e sticks Put the middle bar of indicator head into the stick which between the two sides of sticks firstly And then put the other two bars into the sticks separately See figure 4 The fabricating is completed See figure 5 TARE ZERO HOLD UNIT OFF ON Figure 5 ...

Страница 8: ......

Отзывы: