Operating Manual - SERANA–Q Serial Analogous Indicators
- 9 -
J2: Interfaces
Nº.
Terminal
Description
1
POTI–
Potentiometer – for brightness adjustment
2
POTI IN
Potentiometer wiper for brightness adjustment
3
POTI+
Potenti for brightness adjustment
4
GND
RS485 Ground
5
RS485–
– RS485 interface (for service/calibration)
6
RS485+
+ RS485 interface (for service/calibration)
7
GND
CAN bus Ground
8
CAN L
CAN bus Low
9
CAN H
CAN bus High
10
SHIELD
Shielding
An arbitrary potentiometer with linear characteristics and resistance 1 to 10 k
Ω
can be
connected. It must be connected with 3 poles. The device measures the total resistance
when powered up and then converts it to the required brightness range.
RS485–/+ and CAN L/H must be carried out as twisted pairs!
The CAN bus and the RS485 bus must be terminated each by resistors 120
Ω
on the
first and the last bus participant!
J3: Auxiliary supply
Nº.
Terminal
Description
1
DC IN–
–24 V DC (9 ... 36 V DC)
2
DC IN+
+24 V DC (9 ... 36 V DC)
no shielding required