background image

C:\\HWY_HWYSE112/118EXT

Reinigungssysteme

  ...die sauberste Lösung

1

2

  3                    4             5

6

7

8
9

10

11

12

13

14

15

16

17

18

19

20

21

HWY 118EXT_Schaltkasten

Pos.

No.

Bezeichnung

Description

1

3652458110

Miniaturrelais MY4 24VAC

miniatur relais 

2

3652473404

Schütz 12A 1S+1Ö 24V 50/60Hz

contactor 12 A 

3

3651427520

Hauptschalter für Bodenbefestigunng

mainswitch

4

ETE116200

1

Zeitrelais rückfallverzögernd Typ 51183

electronic timer relais delayed

5

3659151425

1

Verdrahtungskanal LK 4 40/25

PVC installation tube

6

3652291002

12 Durchgangsklemme

terminal block

7

3652299000

Schutzleiter Klemme

ground terminal block

8

3652251201

Schutzleiterklemme USLKG16N

earth terminal

9

3652251110

Reihenklemme UKN16BU

terminal block

10

3652251100

Reihenklemme UKN5BU

terminal block

11

3652251200

Schutzleiterklemme USLKG4

earth terminal

12

ETE600000

1

Transformator RST 100 400V / 24 AC

transformer

13

3652299100

3

Sicherungshalter

fuse holder

14

3652051951

Glasrohrsicherung  5x20 3,15A tr

fuse 5 x 20  3,15 A tr

15

ETE153500

1

Glasrohrsicherung  5 x 20  1,0 A tr

fuse

16

ETE153500

1

Glasrohrsicherung  5 x 20  1,0 A tr

fuse

17

ETE151300

Glasrohrsicherung 5 X 20 0,5A träge

fuse 0,5A

18

3651773209

Motorschutzschalter 6-10A

circuit breaker

19

3651251300

Dreiphasenschine 1065mm SZ PSB 4N power rail 3 ~

20

3651851010

Leitungsschutzschalter B10 1polig 

fuse automat B10

21

3651268220

1

Klemmkasten

power panal

Содержание HWY118 EXT

Страница 1: ...SPARE PART LIST Waschb r SE 112 118 HWY118 EXT Weidner Reinigungssysteme D 74523 Schw bisch Hall Steinbeisweg 29 Telefon 0791 95012 0 Fax 0791 54 742 e mail info weidner cleaning com Internet www weid...

Страница 2: ...Implementing Order oft the Federal Pollution Protection Legislation to ensure that the immission limit values are observed 7 When operatingthe equipmentin rooms a safe discharge ofthe flue gases must...

Страница 3: ...in our list of accessories We will be delighted to help you in the choice accessories and cleaning agents suitable for your cleaning needs 14 Befor working on the high pressure cleaner it must be disc...

Страница 4: ...his control chain as an accessory If workis interruptedfor longerthan 1 minutes the device should be switched offto saveenergy The device is suitable to remove dirt from surfaces by means of a freely...

Страница 5: ...sant hose to the injektor and place the suction filter into the cleansant The quantity of cleansant can be adjusted by turning the hand nut at the cleansant injektor If all the prenamed points are ful...

Страница 6: ...m seperate drum turn the gwitch into the direction 2 If the cleangant tank drum is empty the metering valve should be closed pos since otherwise air will be sucked in and the working pressure will dro...

Страница 7: ...ean or replace unloader valve leaky or soiled nozzle washed out or replace wrong nozzle size oil leak on crankshaft shaft seal faulty replace seal scheck shaft incrased noise with no loss baring worn...

Страница 8: ...Chemical line blocked clean Chemical line faulty replace injector blocked clean injector faulty replace pressure adjustment nozzle too far open closed hp hose too long use a hose w nominal diameter 20...

Страница 9: ......

Страница 10: ...98 EPACA045891 3 Scheibe disk 99 EPACA104360 3 Plungerhalter plunger owner 100 EPACA0456812 3 Dichtungshalter kmpl seal owner 101 EPACA043302 3 lfilz oil felt 106 EPACA043305 3 ND Dichtung ND seal 12...

Страница 11: ...800060 Brennkammer VA Waschb r SE combustion camber 4 ETB220102 Steckdeckel PVC Cover 5 35900001060 Sicherheitsthermostat 95 C mit Tauchh lse safety thermostat with dipping case 6 EPACA00300 Hochdruck...

Страница 12: ...ngssysteme die sauberste L sung Pos No Bezeichnung Description 1418 3882800060 Brennkammer VA Waschb r SE combustion chamber 1423 3656040600 Einschraubheizk rper 403K 600 44 3 B G1 6000W heating unit...

Страница 13: ...panel 6 ETE504300 Elektromotor 3 0 KW 400V 50Hz 1420 Electromotor 3 0 KW 400V 50Hz 1420 7 ETA200035 Schiebeb gel Waschb r ab 06 19999 handle Version after 06 1999 8 3914900010 Rohrschelle 22 mm Alumi...

Страница 14: ...eating 7 ETE186200 Temperaturregler 0 95 C mit Tauchh lse temperature regulator with dipping case 8 ETA200035 Schiebeb gel Waschb r ab 06 19999 handle Version after 06 1999 9 ETA190100 1 Kantenschutz...

Страница 15: ...steme die sauberste L sung HWY 118EXT_Schwimmerventil Pos No Bezeichnung Description 1305 3909900153 1 PVC Kunststoffschwimmer 65 x 130 pvc ball 65 x 130 1304 3909900103 1 Schwimmerventil 3 8 12mm 170...

Страница 16: ...3 8 WE RST Sonder Winkelverschraubung hp fitting 9 5680301500 Schlaucht lle 1 2 AG x 6 mm low pr Fitting 1 2 AG x 6 mm 10 5680301350 T St ck 1 2 Mess AG x IG x IG T pc 1 2 11 ETA350040 4 Gummi Metall...

Страница 17: ...minal block 8 3652251201 Schutzleiterklemme USLKG16N earth terminal 9 3652251110 Reihenklemme UKN16BU terminal block 10 3652251100 Reihenklemme UKN5BU terminal block 11 3652251200 Schutzleiterklemme U...

Отзывы: