Step 4: Use the web-based manager to configure the 

IE-WL-AP-BR-CL-ABG 

Open your computer’s web browser and then type 

http://192.168.1.110 

in the address field to access the web-based 

management homepage. Before the homepage opens, you will need to 
enter the user name and password. For initial configuration, enter the 
default user name and password and then click on the 

Login 

button: 

 User 

name: 

admin 

 Password: 

Detmold 

 

 

ATTENTION 

For security reasons, we strongly recommend changing the 
password. To do so, select 

Maintenance 

Æ

 Password

, and then 

follow the on-screen instructions. 

 

Step 5: Select the operation mode for the 

IE-WL-AP-BR-CL-ABG 

By default, the IE-WL-AP-BR-CL-ABG’s operation mode is set to AP. You 
can change the setting in 

Wireless Settings 

Æ

 

Basic Wireless 

Settings 

if you would like to use Client mode. 

NOTE

To make the change effective, you must click Save Configuration
to save the change or the Save and Restart button to apply all 
changes.

 

Step 6: Test communications 

We will describe two test methods. Use the first method if you are using 
only one IE-WL-AP-BR-CL-ABG, and use the second method if you are 
using two or more IE-WL-AP-BR-CL-ABGs. 

Testing method for one IE-WL-AP-BR-CL-ABG 

If you are only using one IE-WL-AP-BR-CL-ABG, you will need a second 
notebook computer (B) equipped with a WLAN card. Configure the WLAN 
card to connect to the IE-WL-AP-BR-CL-ABG (the default SSID is 

IE-WL-AP-BR-CL-ABG

) and change the IP address of notebook B so 

that it is on the same subnet as the first notebook (A), which is connected 
to the IE-WL-AP-BR-CL-ABG. 

After configuring the WLAN card, establish a wireless connection with the 
IE-WL-AP-BR-CL-ABG and open a DOS window on notebook B. At the 
prompt, type   

ping IP address of notebook A   

and then press the 

Enter 

key. A “Reply from IP address …” response 

means the communication was successful. A “Request timed out.” 
response means the communication failed. In this case, recheck the 
configuration to make sure the connections are correct. 

- 3 - 

Содержание IE-WL-AP-BR-CL-ABG-EU

Страница 1: ...d manual and any further product information if available can be downloaded from the website http www weidmueller com downloads For manual select Print Media then goto Section Industrial Ethernet For...

Страница 2: ...www weidmueller com downloads 1 Cable Holder with a Screw 2 Protective Caps Installation and Configuration Before installing the Wireless Device make sure that all items in the Package Checklist are i...

Страница 3: ...change or the Save and Restart button to apply all changes Step 6 Test communications We will describe two test methods Use the first method if you are using only one IE WL AP BR CL ABG and use the se...

Страница 4: ...hen press Enter key A Reply from IP address response means the communication was successful A Request timed out response means the communication failed In this case recheck the configuration to make s...

Страница 5: ...take it out of the box If you need to reattach the DIN Rail attachment plate to the device make sure the stiff metal spring is situated towards the top as shown in the figures below STEP 1 Insert the...

Страница 6: ...ould be less than 3 5 mm in diameter as shown in the figure at the right Do not screw the screws in all the way leave a space of about 2 mm to allow room for sliding the wall mount panel between the w...

Страница 7: ...wire to determine which wires should be kept separate The rule of thumb is that wiring with similar electrical characteristics can be bundled together Keep input wiring and output wiring separate It...

Страница 8: ...IE WL AP BR CL ABG has one relay output which consists of the two contacts of the terminal block on the IE WL AP BR CL ABG s top panel Refer to the previous section for detailed instructions on how t...

Страница 9: ...e IE WL AP BR CL ABG and plugging in the LAN cable tighten the cable along the device and wall Communication Connections 10 100BaseT X Ethernet Port Connection The 10 100BaseT X ports located on the I...

Страница 10: ...to see the numbers clearly 2 The pin numbers for both 8 pin and 10 pin RJ45 connectors and ports are typically not labeled on the connector or port Refer to the Pinout diagram above to see how RJ45 p...

Страница 11: ...ULT Red Off Error condition does not exist Green Software Ready Green Blink The IE WL AP BR CL ABG has been located by Weidm ller WLAN Administrator interval 1sec STATE Green Re d Red Booting error co...

Страница 12: ...ly Protocols ARP BOOTP DHCP STP RSTP IEEE 802 1D w TX Transmit Power for hardware revision 1 2 802 11b Typ 23 1 5 dBm 1 to 11 Mbps 802 11g Typ 20 1 5 dBm 6 to 24 Mbps Typ 19 1 5 dBm 36 Mbps Typ 18 1 5...

Страница 13: ...15 WARRANTY 5 years Weidm ller gives a 5 year warranty on this product in accordance with the warranty terms as described in the general conditions of sale of the Weidm ller company which has sold the...

Страница 14: ...NTION Use the antennas correctly The 2 4 GHz antennas are needed when the IE WL AP BR CL ABG operates in IEEE 802 11b g The 5 GHz antennas are needed for IEEE802 11a Make sure your antenna installatio...

Отзывы: