background image

Digital Input 

2 electrically-isolated inputs 

 

3 to -30V for state “0” (OFF) 

 

13 to 30V for state “1” (ON) 

 

Max. input current: 8 mA 

Console 

RS-232 (RJ45 type) 

LAN Port 

10/100BaseT(X) auto negotiation speed 

LED Indicators 

PWR1, PWR2, PoE, FAULT, STATE, Signal 
Strength, CLIENT, MODE, BRIDGE MODE, WLAN, 
10M, 100M 

Power

Input Voltage 

12 to 48 VDC, redundant dual DC power inputs or 
48 VDC Power-over-Ethernet (IEEE 802.3af) 

Input Current 

0.494A-0.121A (@ 12-48VDC) 
0.3A @24 VDC 

Reverse Polarity 
Protection 

Present 

Mechanical

Casing 

IP30 protection, aluminum case 

Dimensions 

53.6 x 135 x 105 mm (2.11 x 5.31 x 4.13 in) 

Weight  

850g 

Installation 

DIN-Rail, or wall mounting 

Environmental

Operating Temperature Standard models: 0 to 60°C (32 to 140°F) 

Wide Temp. Models: -40 to 75°C (-40 to 167°F) 

Storage Temperature  -40 to 85ºC (-40 to 185ºF) 
Ambient Relative 
Humidity 

5 to 95% (non-condensing) 

Regulatory Approvals*

Radio EN300 

328 

EMC EN301 

489-1/-17 

EMI FCC 

Part 

15 

WARRANTY 5 

years 

 

Weidmüller gives a 5 year warranty on this product in accordance with the 
warranty terms as described in the general conditions of sale of the Weidmüller 
company which has sold the products to you. Weidmüller warrants to you that 
such products the defects of which have already existed at the time when the 
risk passed will be repaired by Weidmüller free of charge or that Weidmüller 
will provide a new, functionally equivalent product to replace the defective one. 
Safe where expressly described otherwise in writing in this catalogue/product 
description, Weidmüller gives no warranty or guarantee as to the 
interoperability in specific systems or as to the fitness for any particular 
purpose. To the extent permitted by law, any claims for damages and 
reimbursement of expenses, based on whatever legal reason, including contract 
or tort, shall be excluded. Where not expressly stated otherwise in this warranty, 
the general conditions of purchase and the expressive liability commitments 
therein of the respective Weidmüller company which has sold the products to 
you shall be applicable. 

 
 
 
 

- 13 - 

Содержание IE-WL-AP-BR-CL-ABG-EU

Страница 1: ...d manual and any further product information if available can be downloaded from the website http www weidmueller com downloads For manual select Print Media then goto Section Industrial Ethernet For...

Страница 2: ...www weidmueller com downloads 1 Cable Holder with a Screw 2 Protective Caps Installation and Configuration Before installing the Wireless Device make sure that all items in the Package Checklist are i...

Страница 3: ...change or the Save and Restart button to apply all changes Step 6 Test communications We will describe two test methods Use the first method if you are using only one IE WL AP BR CL ABG and use the se...

Страница 4: ...hen press Enter key A Reply from IP address response means the communication was successful A Request timed out response means the communication failed In this case recheck the configuration to make s...

Страница 5: ...take it out of the box If you need to reattach the DIN Rail attachment plate to the device make sure the stiff metal spring is situated towards the top as shown in the figures below STEP 1 Insert the...

Страница 6: ...ould be less than 3 5 mm in diameter as shown in the figure at the right Do not screw the screws in all the way leave a space of about 2 mm to allow room for sliding the wall mount panel between the w...

Страница 7: ...wire to determine which wires should be kept separate The rule of thumb is that wiring with similar electrical characteristics can be bundled together Keep input wiring and output wiring separate It...

Страница 8: ...IE WL AP BR CL ABG has one relay output which consists of the two contacts of the terminal block on the IE WL AP BR CL ABG s top panel Refer to the previous section for detailed instructions on how t...

Страница 9: ...e IE WL AP BR CL ABG and plugging in the LAN cable tighten the cable along the device and wall Communication Connections 10 100BaseT X Ethernet Port Connection The 10 100BaseT X ports located on the I...

Страница 10: ...to see the numbers clearly 2 The pin numbers for both 8 pin and 10 pin RJ45 connectors and ports are typically not labeled on the connector or port Refer to the Pinout diagram above to see how RJ45 p...

Страница 11: ...ULT Red Off Error condition does not exist Green Software Ready Green Blink The IE WL AP BR CL ABG has been located by Weidm ller WLAN Administrator interval 1sec STATE Green Re d Red Booting error co...

Страница 12: ...ly Protocols ARP BOOTP DHCP STP RSTP IEEE 802 1D w TX Transmit Power for hardware revision 1 2 802 11b Typ 23 1 5 dBm 1 to 11 Mbps 802 11g Typ 20 1 5 dBm 6 to 24 Mbps Typ 19 1 5 dBm 36 Mbps Typ 18 1 5...

Страница 13: ...15 WARRANTY 5 years Weidm ller gives a 5 year warranty on this product in accordance with the warranty terms as described in the general conditions of sale of the Weidm ller company which has sold the...

Страница 14: ...NTION Use the antennas correctly The 2 4 GHz antennas are needed when the IE WL AP BR CL ABG operates in IEEE 802 11b g The 5 GHz antennas are needed for IEEE802 11a Make sure your antenna installatio...

Отзывы: