EN
WECOUNT | 23
Overview of event and error messages
No.
Type
Description
Measures
Err01
System error
Memory error,
detection defective
Replace device
Err02
BatLow
Battery voltage too low
Replace device
Err03
Manipulation Fraud attempt
(magnetic field)
Counter no
longer
valid for billing
InF04
Radio error
The meter no longer trans-
mits a radio signal�
Check device
InF05
Pipe burst
Over a period of 24 hours an
extremely high water con-
sumption was determined�
Check pipe
network
InF06
Leakage
The water has not been
standing still for 24 hours,
which indicates a permanent
loss of water� (After 30 min
stop the error is automati-
cally reset)�
Check pipe net-
work for leaks
InF07
Qmax error
An inadmissibly high water
flow rate has been detected,
which may cause damage to
the meter�
Check meter
and pipe net-
work
InF08
backflow
error
Water runs through the me-
ter in the wrong direction�
Check water
meter instal-
lation
Err09
Battery end
End of the device's lifetime
reached
Replace device
Содержание MODULARIS MTK-OZX
Страница 7: ...EN Water meter 7 Device dimensions Required tools H 35 65 mm ...
Страница 11: ...EN Installation guide 11 Installing the water meter OFF WGU HT2 1 2 ...
Страница 12: ...EN 12 Installation guide A B 3 4 ...
Страница 13: ...EN Installation guide 13 5 6 ...
Страница 14: ...EN 14 Installation guide A B IST MUK MET MOC MOE 7 8 ...
Страница 15: ...EN Installation guide 15 A B MB2 IST TE1 MET MOC MOE max 40 Nm A34 DM1 MUK HT2 MB2 MB3 WE1 WGU max 80 Nm 9 10 ...
Страница 16: ...EN 16 Installation guide ON ON 11 ...