EN
10 | For your safety
Safety notes and hazard warnings
Improper assembly, pressure tests, modifications or incorrect
operation can cause personal injury and damage to property�
X
If the seal is damaged or removed, the water meter is no longer
licenced for legal metering�
X
Check water meter for transport damage before installation�
X
Do not drop, never hold by the protective cover or counter�
X
If the water meter has fallen down, it must not be installed
anymore�
Pressure shocks in the pipe may damage the meter!
Present air pockets falsify the measurement result�
X
Only use KTW/TVO compliant lubricants that are suitable for
EPDM gaskets�
X
Water meters may only be installed after a pressure test�
X
Water meters may only be installed in pipes that have already
been leak-tested, flushed and vented and they must be well
vented before commissioning�
X
Make sure that the water meter is always filled with water�