NAVE

 

II

Q

UICK 

S

TART 

G

UIDE

 

www.wegener.com

 

5

 

800026-02 Rev. A

 

Figure 5: 

NAVE IIc Web Interface Stream Info Page 

 

Figure 6: 

NAVE IIc Web Interface SID Assignment Page 

 

NOTE:

 You must 

login

 to add the SID and Assignment choices. (See 

10. 

Password-Protected Web Pages

 for default 

Login User Names

 and 

Password

s.) 

Figure 7: 

NAVE IIc SID Assignment Page During Editing 

 

a. 

Once you have logged in, first enter the 

SID

 and 

Check Digits

 

assigned to you by the 

Nielsen Encoder Support Group

. The 

Check 

Digits

 will be two letters following the 

SID Number

. The 

Check Digits

 

must be entered as 

capital letters

. If your transmission has more than 

one program in it, you must assign the correct 

SID

 for the correct 

program content. 

 

NOTE:

 The 

Nielsen Encoder Support Group

 will supply this information to you. 

 

b. 

Next, select how you want to assign the 

SID

: you can choose 

Major/ 

Minor

Program Number

, or 

Audio PID

 from a drop-down selection box. 

 

c. 

Depending on the 

Selection Mode

 chosen in 

Step c

, the appropriate 

type of information box will display for you to enter the stream ID data. 

 

d. 

Next, select the type of 

Insertion:

 

Overwrite

 or 

Refrain

 (from overwriting 

an existing SID) in the stream. (The 

Nielsen Encoder Support Group 

can instruct you about the 

Insertion

 settings.) The preferred mode is 

Overwrite

 

e. 

Repeat 

Steps 

b

 - 

d

 for each program in the stream.

 

Содержание Nielsen NAVE IIc

Страница 1: ... com 1 Remove the NAVE IIc ac power cord and CD ROM Manual from the shipping carton Call your shipping carrier immediately if any damage is discovered 2 Remove the clear plastic covering from around the bottom of the unit and over the LCD window on the front panel 3 Place the NAVE IIc indoors on a well supported flat table or desktop or mount it in a standard equipment rack If rack mounting your N...

Страница 2: ...l a The Liquid Crystal Display LCD provides menu data and input screens to the user Menu screens are entry points to additional screens These may be data screens that display signal or unit status information or input screens where settings can be changed by the user b The NAVE IIc s Home screen displays the unit s input output stream type ASI or SMPTE310M the TSID number in hex as read from the i...

Страница 3: ...d Constant A warning has been issued recently See error log for details Warning Yellow Off No current Warning condition exists Table 1 Front Panel LED Indicator Descriptions Continued LED Label LED Color LED STATE Meaning Constant An error has occurred See error log for details Alarm Red Off No current Alarm condition exists Constant The encoder is in firmware bypass mode System Bypass Red Off No ...

Страница 4: ...essage APPLYING IP SETTINGS PLEASE WAIT and then display the new DHCP assigned IP address g If you need a Static IP address but a different IP address or Subnet Mask than the default settings then use Z to move one screen to the right until you see the screen with IP ADDRESS with the default address below it NOTE For IP addresses that include subfields with leading zeros you must enter those zeros...

Страница 5: ... entered as capital letters If your transmission has more than one program in it you must assign the correct SID for the correct program content NOTE The Nielsen Encoder Support Group will supply this information to you b Next select how you want to assign the SID you can choose Major Minor Program Number or Audio PID from a drop down selection box c Depending on the Selection Mode chosen in Step ...

Страница 6: ...asswords Page Name User Name Password SID Assignment config config Configuration config config Service service service The Service User Name and Password provide access to all password protected pages Users with config privileges have access to the SID Assignment and Configuration pages which handle the normal unit and data stream configuration processes 11 Completing the NAVE IIc Encoder Configur...

Страница 7: ...eral purpose input 3 General purpose input 4 General purpose input 5 General purpose input 6 User Relay N C contact User Relay COM contact User Relay N O contact GND Alarm N O contact OK COM closes here when unit OK Alarm COM contact Alarm N C contact Alarm COM closes here on alarm or if power is off GND Table 5 NAVE IIc Encoder Interconnect Descriptions Continued Connector Label Connector Type Pi...

Страница 8: ... Network window in order to install the adapter TCP IP or Client for Microsoft Networks A 2 2 If you need the Ethernet Network Adapter a Click Add b Select Adapter then click Add again c Select the manufacturer and model of your Ethernet adapter and click OK A 2 3 If you need TCP IP a Click Add b Select Protocol then click Add again c Select Microsoft d Select TCP IP and click OK A 2 4 If you need...

Страница 9: ...sh to configure Select Properties e The LAN Properties dialog window appears A 4 2 Setting the Encoder s TCP IP Address a Select Internet Protocol TCP IP b Click Properties The Internet Protocol Properties dialog window appears c Select the Use the following IP address radio button d Enter the static IP address 10 61 62 62 in the first field e Enter the Subnet Mask 255 255 255 0 in the second fiel...

Страница 10: ...riod of one year after shipment to customer WEGENER s obligation under this warranty is limited to repairing or at WEGENER s option replacing parts subassemblies or entire assemblies WEGENER shall not be liable for any special indirect or consequential damages This warranty does not cover parts or equipment which have been subject to misuse negligence or accident by the customer during use All shi...

Отзывы: