Wegener Nielsen NAVE IIc Скачать руководство пользователя страница 10

NAVE

 

II

Q

UICK 

S

TART 

G

UIDE

 

 

 

800026-02 Rev. A 

10

 

www.wegener.com

 

Data, drawings, and other material contained herein are proprietary to 

Wegener 

Communications, Inc.

, and may not be reproduced or duplicated in any form without the prior 

written permission of 

Wegener Communications, Inc.

 

The information contained herein is subject to change without notice. Revisions may be issued to 
advise of such changes and/or additions. 

WEGENER

®

 is a trademark of 

Wegener Communications, Inc.

 All other trademarks are the 

property of their respective owners. 

©

2005 

Wegener Communications, Inc.

 All Rights Reserved. 

The 

Wegener NAVE IIc

 is approved under 

FCC Part 15B Class A

 and 

UL 60950 3rd Edition

Warranty: 

The following warranty applies to all

 WEGENER

 products:  

All 

WEGENER

 products are warranted against defective materials and workman-ship for a 

period of one year after shipment to customer.  

WEGENER

’s obligation under this warranty is 

limited to repairing or, at 

WEGENER

’s option, replacing parts, subassemblies, or entire 

assemblies. 

WEGENER

 shall not be liable for any special, indirect, or consequential damages.  

This warranty does not cover parts or equipment, which have been subject to misuse, 
negligence, or accident by the customer during use.  All shipping costs for warranty repairs 
shall be prepaid by the customer. There are no other warranties, expressed or implied, except 
as stated herein. 

Technical Support 

This guide provides information for setup and initial operation of the 

NAVE IIc Encoder

Additional information may be found in the 

User's Manual

 (p/n 800026-01) on the CD-ROM 

packed with the unit, or on the 

www.wegener.com 

web site. (Click 

Support

, then select 

Manuals and Code Downloads

, and search for the 

NAVE IIc

 in the 

Manuals

 product list.) 

WEGENER  

(Corporate Office)

 

11350 Technology Circle 
Duluth, GA 30097 

WEGENER  
Customer Service

  

359 Curie Drive 
Alpharetta, GA 30005 

 

 

Содержание Nielsen NAVE IIc

Страница 1: ... com 1 Remove the NAVE IIc ac power cord and CD ROM Manual from the shipping carton Call your shipping carrier immediately if any damage is discovered 2 Remove the clear plastic covering from around the bottom of the unit and over the LCD window on the front panel 3 Place the NAVE IIc indoors on a well supported flat table or desktop or mount it in a standard equipment rack If rack mounting your N...

Страница 2: ...l a The Liquid Crystal Display LCD provides menu data and input screens to the user Menu screens are entry points to additional screens These may be data screens that display signal or unit status information or input screens where settings can be changed by the user b The NAVE IIc s Home screen displays the unit s input output stream type ASI or SMPTE310M the TSID number in hex as read from the i...

Страница 3: ...d Constant A warning has been issued recently See error log for details Warning Yellow Off No current Warning condition exists Table 1 Front Panel LED Indicator Descriptions Continued LED Label LED Color LED STATE Meaning Constant An error has occurred See error log for details Alarm Red Off No current Alarm condition exists Constant The encoder is in firmware bypass mode System Bypass Red Off No ...

Страница 4: ...essage APPLYING IP SETTINGS PLEASE WAIT and then display the new DHCP assigned IP address g If you need a Static IP address but a different IP address or Subnet Mask than the default settings then use Z to move one screen to the right until you see the screen with IP ADDRESS with the default address below it NOTE For IP addresses that include subfields with leading zeros you must enter those zeros...

Страница 5: ... entered as capital letters If your transmission has more than one program in it you must assign the correct SID for the correct program content NOTE The Nielsen Encoder Support Group will supply this information to you b Next select how you want to assign the SID you can choose Major Minor Program Number or Audio PID from a drop down selection box c Depending on the Selection Mode chosen in Step ...

Страница 6: ...asswords Page Name User Name Password SID Assignment config config Configuration config config Service service service The Service User Name and Password provide access to all password protected pages Users with config privileges have access to the SID Assignment and Configuration pages which handle the normal unit and data stream configuration processes 11 Completing the NAVE IIc Encoder Configur...

Страница 7: ...eral purpose input 3 General purpose input 4 General purpose input 5 General purpose input 6 User Relay N C contact User Relay COM contact User Relay N O contact GND Alarm N O contact OK COM closes here when unit OK Alarm COM contact Alarm N C contact Alarm COM closes here on alarm or if power is off GND Table 5 NAVE IIc Encoder Interconnect Descriptions Continued Connector Label Connector Type Pi...

Страница 8: ... Network window in order to install the adapter TCP IP or Client for Microsoft Networks A 2 2 If you need the Ethernet Network Adapter a Click Add b Select Adapter then click Add again c Select the manufacturer and model of your Ethernet adapter and click OK A 2 3 If you need TCP IP a Click Add b Select Protocol then click Add again c Select Microsoft d Select TCP IP and click OK A 2 4 If you need...

Страница 9: ...sh to configure Select Properties e The LAN Properties dialog window appears A 4 2 Setting the Encoder s TCP IP Address a Select Internet Protocol TCP IP b Click Properties The Internet Protocol Properties dialog window appears c Select the Use the following IP address radio button d Enter the static IP address 10 61 62 62 in the first field e Enter the Subnet Mask 255 255 255 0 in the second fiel...

Страница 10: ...riod of one year after shipment to customer WEGENER s obligation under this warranty is limited to repairing or at WEGENER s option replacing parts subassemblies or entire assemblies WEGENER shall not be liable for any special indirect or consequential damages This warranty does not cover parts or equipment which have been subject to misuse negligence or accident by the customer during use All shi...

Отзывы: