14. MALFUNCTIONS and CORRESPONDING SOLUTIONS
Indication
Cause
Solution
MACHINE LACKING
POWER
1) The machine switch is in the "0" position.
2) The mains power supply switch is in the OFF position.
1) Turn the machine switch to the "1" position.
2) Place the mains switch in the ON position.
NO WATER IN BOILER
There is no water in the internal tank.
Fill the tank with water.
TOO MUCH WATER
IN BOILER
Malfunction of the electrical system or hydraulic
system.
Contact Technical Service.
STEAM DOES NOT COME
OUT OF NOZZLES
1) The nozzle sprayer is clogged.
2) The machine switch is in the "0" position.
1) Clean the steam nozzle sprayer.
2) Turn the machine switch to the "1" position.
STEAM MIXED WITH
WATER COMES OUT OF
THE NOZZLES
Malfunction of the electrical system or hydraulic
system.
Contact Technical Service.
NO DISPENSING
There is no water in the internal tank.
Fill the tank with water.
WATER LEAKS FROM
THE MACHINE
The draining tray is full.
Empty the draining tray.
COFFEE IS TOO HOT or
TOO COLD
Malfunction of the electrical system or hydraulic
system.
Contact Technical Service.
THE PRESSURE GAUGE
INDICATES AN UNAC-
CEPTABLE PRESSURE
Malfunction of the electrical system or hydraulic
system.
Contact Technical Service.
COFFEE GROUNDS
IN CUP
The lower perforator does not conform.
Replace the lower perforator.
DISPENSING IS
DIFFICULT