1. GENERAL INFORMATION

WECM / Emerald eZA

 product is an Electronically Commutated Motor composed by a permanent magnet motor and a 

drive with features customized for commercial ventilation solutions.
This Manual contains only the required information that allows qualified and trained personnel to carry out their services. 
The product images are shown for illustrative purpose only.

1.1. WARNINGS IN THIS MANUAL

ATTENTION!

The information mentioned in this warning is important for the proper understanding and good operation of the 
product.

ATTENTION!

The procedures recommended in this warning have the purpose of avoiding material damage.

DANGER!

The procedures recommended in this warning have the purpose of protecting the user against death, serious 
injuries and considerable material damage.

2. SAFETY MEASURES

Only trained personnel, with proper qualifications, and familiar with this kind of equipment and associated machinery shall 
plan and implement the installation, starting, operation and maintenance of this equipment. The personnel shall follow all 
the safety instructions described in this manual and/ or defined by the local regulations.

DANGER!

Always disconnect the main power supply before touching any electrical device associated with the product. 
Several components may remain charged with high voltage and/or in movement and may cause injuries to 

people, even after the AC power supply has been disconnected or turned off. Wait at least 10 minutes to guarantee the 
fully discharge of capacitors. Always connect the equipment to the ground protection (PE)

ATTENTION!

Contains permanent magnets. For pacemaker users, it is recommended to avoid close or prolonged contact with 
this product, as it may interfere with the proper operation of the device.

++

ATTENTION!

Any service on the internal parts of the motor must be performed by qualified personnel only, since, due to the 
attraction between metallic parts caused by the magnets, risk of accident is present both in the assembly and 

disassembly of the motor.

3. SHIPMENT, STORAGE AND HANDLING

Check the conditions of the motor immediately upon receipt. Where any damage is noticed, this must be reported in writing 
to the transportation company, and immediately communicated to the insurance company and to WEG. In this case, no 
installation job can be started before the detected problem has been solved.
Check if the nameplate data matches the invoice data and the environmental conditions in which the motor will be installed. 
If the motor is not immediately installed, it must be stored in a clean and dry room protected against dust, vibrations, gases 
and corrosive agents, and with temperature between -25 ºC and 60 ºC and relative humidity not exceeding 60%.
If the motors are stored for more than two years, it is recommended to change the bearings, or to remove, wash, inspect 
and relubricate them before the motor is started.

DANGER!

g   

Always handle the motor carefully in order to prevent personal injuries and impacts that could damage the 

bearings.

 

When available, do not lift and/or carry the product holding by the input cables.

 

When available, use only the eyebolts to lift the motor. However, these eyebolts are designed for the motor weight 

only. Thus, never use these eyebolts to lift the motor with additional loads coupled to it. For multimounting motors (with 
removable feet/ base), the eyebolts must be positioned according to the motor mounting position so that the lifting angle 
is vertically aligned (lifting at 0°).

 

Additional information regarding the maximum allowable angle-of-inclination is indicated in the general manual 

available on the website www.weg.net.

Содержание WECM

Страница 1: ...www weg net WECM Emerald eZA Manual 1 WECM Emerald eZA Three Phase Motors Installation Operation and Maintenance Manual Motors Automation Energy Transmission Distribution Coatings...

Страница 2: ...e we advise to make a careful and detailed study of the instructions contained herein before performing any procedures on the motor The noncompliance with the instructions informed in this manual and...

Страница 3: ...roduct as it may interfere with the proper operation of the device ATTENTION Any service on the internal parts of the motor must be performed by qualified personnel only since due to the attraction be...

Страница 4: ...erformed according to the applicable standards and that the shaft key has been securely fastened before the motor is started When available do not lift and or carry the product holding by the input ca...

Страница 5: ...verhung loads include belt tension and weight of sheave 3 Overhung load limits do not include any effect of unbalanced magnetic pull Only remove the corrosion protection grease from the shaft end and...

Страница 6: ...IP66 the drain plugs must remain at closed position being opened only during the motor maintenance procedures Slinger WECM Emerald product in vertical shaft up mounting should be fitted with water sl...

Страница 7: ...solid grounded neutral 5 2 CONTROL CONNECTIONS Make the control connections following nameplate indication Three phase DC voltage VDC and GND terminals DC current ADC and GND terminals Frequency duty...

Страница 8: ...o select between local or remote speed adjust Remove the lid from the back side of the drive cover Use the DIP switch identified as L R to select between local L or remote R Reinstall the lid to the b...

Страница 9: ...agea Lower than 2 VDC Zero motor is off From 2 to 10 VDC Maxb Minc 8 ISd 2 Min DC current Lower than 4 mA DC Zero motor is off From 4 to 20 mA DC Maxb Minc 16 ISd 4 Min Frequency Lower than 10 Zero mo...

Страница 10: ...value for the remote speed adjust signals can be changed Using the optional WEG EC Motor Speed Controller see item 6 5 Using the product local tact buttons only up to the maximum speed set by WEG EC M...

Страница 11: ...the back side of drive cover after the connections are done Maximum speed adjust Remove the lid from the back side of the drive cover Connect the external controller to the EC motor using the cable su...

Страница 12: ...regime considering the critical and special use of this function NOTE When the user activates the Fire Mode function he she acknowledges that the protection functions of the WECM Emerald eZA are disab...

Страница 13: ...g Figure 11 Modbus connecting After completing the above preparations please turn on the power of the ECM Motor Confirm the ECM Motor Modbus slaver address The default address is 0x55 85 2 Operation i...

Страница 14: ...and click write Figure 15 Step 3 After write in the new address the old one is disable Input the new address in Node and check communication Figure 16 Figure 15 Write address Figure 16 Check communic...

Страница 15: ...different serial configuration The serial parameters of inverter can be changed by Modbus command The register 0x0008 is used to set the baud rate writing the corresponding baud rate in the register 0...

Страница 16: ...00 08 00 03 06 96 00 00 02 00 01 D4 88 10 The slaver responses format R 13 33 31 114 55 10 00 08 00 03 0C 1E When slaver responses it means setting successfully 9 Modbus command and address 01 Request...

Страница 17: ...troller Read Register address 0x0002 R 03 FCT Max Speed Read Register address 0x0003 R 03 Current Max Speed Read Register address 0x0004 R 03 Read motor Target speed Read Register address 0x0005 R 03...

Страница 18: ...ss 0000 Table 9 Register table 11 Fault error code Error Code Fault Description 0x0001 DCBUS LOW 0x0002 DCBUS HIGH 0x0003 OVER CURRENT HARDWARE PROTECTION 0x0004 TEMPERATURE CRITICALLY HIGH 0x0005 LOC...

Страница 19: ...s Motor model Batch number and manufacturing date available in the motor nameplate refer to item 4 Installed software version available in the drive label refer to item 4 8 MAINTENANCE DANGER g Before...

Страница 20: ...hnical documents especially those set out in the product Installation Operation and Maintenance Manual as well as the applicable standards and regulations in force in each country Defects arising from...

Страница 21: ...position IM code EN 60034 8 2007 A1 2014 Rotating electrical machines Part 8 Terminal markings and direction of rotation EN 60034 9 2005 A1 2007 Rotating electrical machines Part 9 Noise limits EN 60...

Страница 22: ...en installed maintained and used in applications for which they were designed and in compliance with the relevant installation standards and manufacturer s instructions comply with the provisions of t...

Страница 23: ...ey were designed and in compliance with the relevant installation standards and manufacturer s instructions comply with the provisions of the following relevant United Kingdom statutory requirements w...

Страница 24: ...6 4000 motores weg net www weg net The values shown are subject to change without prior notice The information contained is reference values Cod 50119773 Rev 00 Date m a 05 2022 MOTORS For WEG s world...

Отзывы: