![WEG Drive Scan Скачать руководство пользователя страница 35](http://html1.mh-extra.com/html/weg/drive-scan/drive-scan_manual_950705035.webp)
5
CONNECTING A DEVICE TO THE DRIVE SCAN
Table 5.13:
Parameters related to the RS-485 communication accessories
Parameter
Description
Values range
P0311
Serial interface byte configuration
0 = 8 bits, no parity, 1 stop bit
1 = 8 bits, even parity, 1 stop bit
2 = 8 bits, odd parity, 1 stop bit
3 = 8 bits, no parity, 2 stop bits
4 = 8 bits, even parity, 2 stop bits
5 = 8 bits, odd parity, 2 stop bits
P0312
Serial protocol
2 = Modbus RTU
P0313
Action for communication error
0 = Inactive
1 = Ramp stop
2 = General disable
3 = Go to local
4 = Go to local e mantém comandos e referência
5 = Fault cause
P0314
Serial watchdog
0,0 a 999,0 s
P0316
Serial interface status
0 = Inactive
1 = Active
2 = Watchdog error
5.5.2 ETHERNET
To connect to the WCD-ED300 via Ethernet GbE1 communication interface, using the Modbus TCP protocol, it is
necessary to install on the CFW500 one of the accessories listed in
Table 5.14
.
Table 5.14:
Ethernet hardware accessories of the CFW500 compatible with the Modbus TCP protocol
Accessory
WEG Item
Modbus TCP
clients
Firmware
CFW500
Parameters
CETH-IP
12892814
2
≥
V2.00
Table 5.15
CEMB-TCP
12892815
4
Table 5.15:
Parameters related to the CETH-IP and CEMB-TC accessories
Parameter
Description
Values range
P0800
Ethernet module identification
0 = Not identified
1 = Modbus TCP
2 = Ethernet/IP
3 = PROFINET IO
P0801
Ethernet communication status
0 = Setup
1 = Init
2 = Wait Comm
3 = Idle
4 = Data Active
5 = Error
6 = Reservado
7 = Exception
8 = Access Error
P0803
Ethernet baud rate
0 = Auto 1 = 10 Mbps, half duplex
2 = 10 Mbps, full duplex
3 = 100 Mbps, half duplex
4 = 100 Mbps, full duplex
P0806
Modbus TCP watchdog
0 a 65,5 s
P0810
IP address configuration
0 = Parameters
1 = DHCP
Low Voltage Devices | 5-16
Содержание Drive Scan
Страница 2: ......
Страница 4: ...Summary of reviews Version Revision Description 1 0X 00 First edition...
Страница 11: ...2 INSTALLATION RECOMMENDATIONS Low Voltage Devices 2 2...
Страница 58: ...6 SETTING THE DRIVE SCAN ON THE MFM Figure 6 22 RS 485 network con guration Low Voltage Devices 6 13...
Страница 59: ...6 SETTING THE DRIVE SCAN ON THE MFM Low Voltage Devices 6 14...
Страница 71: ...8 SETTING THE IP ON WINDOWS 10 Click on OK Figure A 7 Figure A 7 Changing IP Low Voltage Devices 8 3...
Страница 72: ......
Страница 73: ......