To Prevent Electrical Shock, Be Sure To Take The Following Precautions: 

1. 

Make sure the unit is grounded. Always connect power to a grounded receptacle. 

2. 

Do not stress the AC power cord.  

3. 

Do not bump, hit, pour water/liquids or otherwise subject the fusion wand to physical 

shock. This may damage the heater, or result in an electrical shock. 

4. 

While there are no user serviceable parts, it is important to always turn off and 

unplug the system before starting any repairs or maintenance. An electric shock can 

result in serious injury or death. 

5. 

Do not expose the unit to moisture or operate the unit with wet hands. 

6. 

When finished, turn the power switch off and remove the AC power cord from the 

wall.  

7. 

Do not modify the unit. 

 

OPERATIONAL WARNINGS: 

 

  To extend the life of the heating element, avoid using a 

low air flow

 and/or 

high 

temperature continuously

. The heating element has a duty cycle of a maximum 20 

minutes of continuous use. It is very important to ensure that the welding wand is 

placed back on its docking cradle in order to completely cool down between welding 

operations. Do not switch the fusion wand on while it is in the cooling stand. Failure 

to comply with these instructions may result in damage to the unit. 

  Do not aim the hot air at your eyes or others as serious eye damage may occur. 

  The fusion wand produces a lot of heat during operation. Do not allow the heater 

and nozzle to contact exposed skin as burns will occur.  

  Death or serious injury may result from electric shock.  

  The metal nozzle operates at a high temperature. Keep the hot air away from the 

body, clothes and flammable material when in operation. Do not touch the nozzle! 

Always replace the fusion wand to its original holder when not being use. The metal 

nozzle will remain hot for some time after being switched off.  

  Do not block the nozzle, or it may overheat and damage the heating element.  

  Do not leave the system unattended when it is powered on.  

  Do not use if damaged: If the Fusion Plus+ becomes faulty, discontinue use 

immediately.  

  Unplug the system power cord when not in use. 

Содержание FUSION PLUS

Страница 1: ...1 Faster Smarter Better OPERATING MANUAL PN WS 1000 Wedge Clamp Systems Inc 170 21320 Gordon Way Richmond BC V6W 1J8 Tel 604 207 9595 Fax 604 207 9593 Toll Free 1 800 615 9949...

Страница 2: ...ODUCT DESCRIPTION 3 INTRODUCTION 3 OPERATIONAL WARNINGS 4 PRODUCT FEATURES 5 DISPLAY FUNCTIONS OPERATION 5 OPERATING PROCEDURES 6 CHANNEL PROGRAMMING 6 PROGRAMMING 7 Auto Off function 8 Temporary Powe...

Страница 3: ...e tip Be sure to comply with the following warnings and cautions for your safety 1 Power to the unit should be 110VAC 2 Prior to use check the unit for any shipping damage 3 During operation the head...

Страница 4: ...ntinuous use It is very important to ensure that the welding wand is placed back on its docking cradle in order to completely cool down between welding operations Do not switch the fusion wand on whil...

Страница 5: ...ATION No FUNCTION DESCRIPTION 1 Heating Solid lit display indicates that the system is coming to temperature When it flashes the temperature is being maintained at the set temperature 2 Cooling In the...

Страница 6: ...an be manually changed to any combination of settings Using the select button on the fusion wand will toggle through Channels 1 3 presets 5 When the Display temperature reaches the desired Set tempera...

Страница 7: ...is 212 F 932 F Press the SET key to adjust the desired airflow for CH1 The digits will start to flash and the air volume can be adjusted from 0 200 Without adjustment CH1 and the temperature will sta...

Страница 8: ...usion wand in its stand The heating element turns off and the cooling cycle begins indicated by the presence of the snowflake icon on the left of the screen As the fusion wand cools down below 212 F t...

Страница 9: ...where the rod just begins to stick to the surface 7 Start the weld approximately 6 mm ahead of the weld joint using slight downward pressure on the rod at a 90 degree angle to the repair surface Allow...

Страница 10: ...ll amount of welding rod into the V groove using the hot air flow from the fusion wand once again starting slightly before the weld joint 19 Press the repair rod into the plastic moving at a rate that...

Отзывы: