PRODUCT FEATURES
•
The solid state Fusion Plus+ electronic module features an intuitive lighted LCD
touch screen display and precision microprocessor controlled heat/flow settings.
•
A temperature sensor installed inside the heating element of the wand provides fast
and accurate temperature control directly at the tip.
•
The Fusion Pro Station is encased in a sturdy 580 pound capacity, 4-Drawer powder
coated cart.
•
System repair or service is made fast and easy. The integrated electronic module is
a plug and play replacement that can be removed/replaced by the shop, on site in 5
minutes. Heating elements, air filters can all be replaced simply and easily.
•
Auto-cooling design: When the Fusion Plus+ wand is placed in its docking cradle,
the heater turns off and the flow of air automatically switches to high to cool the unit
down rapidly.
•
Constant feedback from the temperature sensor at the heating element
automatically protects the product from an over temp condition.
DISPLAY FUNCTIONS & OPERATION
No. FUNCTION
DESCRIPTION
1
Heating
Solid lit display indicates that the system is coming to temperature.
When it flashes, the temperature is being maintained at the set
temperature.
2
Cooling
In the auto cool down cycle, it indicates the decreasing temperature.
3
Standby
When this icon appears on screen it shows that they element is in
standby mode, and the heat gun is at or near room temperature.
4
Set
Temperature
Use the arrow buttons to set the temperature to a desired
level, which is displayed here. CH0 is the default
operating mode, 212 – 932 °F
5
Channel Preset CH1, CH2, CH3 preset temperature setting accessed by
pressing the button on the fusion wand.
6
Adjust
Temperature/Air
Flow
Press Up arrow ▲to increase set temperature and air flow ,down arrow
▼ to decrease.
7
Display
Temperature
This indicates the temperature at the fusion wand tip.
8
„Cal‟
-
Correction
Value
Used to calibrate the heating element. The „Cal‟ function
is accessed from the SET button. This requires a precision
thermometer.
9
Set & Enter
Press SET to activate Channel presets, and activate Cal
function, and press ENTER to confirm the temperature
once set.
10 Channel Preset
Select
Press the button on the fusion wand to select Channels CH1 – CH3