Wecon LX3V-2TC-BD Скачать руководство пользователя страница 5

                                                                                                                                                     

LX3V-2TC-BD

 

4                                                       

                                                                                  WECON Technology Co., Ltd.

 

AWG26 

0.1288 

Stranded cable: stripped jacket, rub 

Conductor, then connect the cable. 
Single-core  cable:  stripped  jacket, 

Then connect the cable. 

 

  ...... 

...... 

AWG16 

1.309 

 

5.2 Input 

 

Figure 5-1 

 

6.

 

Examples 

The analog values of each channel are transfer to digital values and stored in D8112&D8113. 

6.1 Basic Program Examples 

Set CH1 and CH2 as thermocouple input mode, and stored value in D0 and D2. 

 

 

6.2. Examples of Applications 

Since the LX3V-2TC-BD does not have offset and gain functions, if it needs for the values out of    the 

standard specifications, Additional programming orders will be needed to multiply or divide the converted 
value. 

 

Caution 

Since the use of additional programming orders, the converted precision and resolution of the analog 

Set CH1 as K-type thermocouple input mode 

Set CH1 as K-type thermocouple input mode 
Set the digital value of D0 into analog value 

Set the digital value of D2 into analog value 

Содержание LX3V-2TC-BD

Страница 1: ...ON LX3V 2TC BD Module Website http www we con com cn en Technical Support liux we con com cn Skype fcwkkj or Jason chen842 Phone 86 591 87868869 QQ Group 465230233 Technical forum http wecon freeforums net ...

Страница 2: ...ead to failure 3 BD module and top cover of PLC s tightening torque is 0 3 0 6 N m Warring Make sure to power off the PLC before mounting or removing the BD module and put the cover in right place 2 Special feature 1 LX3V 2TC BD module equips with 2 channels analog output This module will be mounted in the PLC so there is no need to change the installation area of the PLC 2 The type to AD convert ...

Страница 3: ... the measurement range 4 LED4 TC 2 On indicates enable OFF indicates disable flicker indicates exceeding the measurement range If the BD module is plugged into the old firmware version when on the host all LEDs will be flashing 4 Specifications 1 Please refer to the LX3V user manual for the general specification of LX3V 2TC BD 2 LX3V 2TC BD is powered supply by LX3V main unit Table 4 1 Item Explan...

Страница 4: ...re cut off the electricity before installation disassembly to prevent electric shock or product damages Caution 1 Stay away from high voltage cables to avoid interference or surge 2 Grounding is required but please do not share the ground site with high voltage cable 3 Do not weld any cable ends and make ensure that the number of connecting cables no more than a predetermined number 4 Do not conne...

Страница 5: ...ple input mode and stored value in D0 and D2 6 2 Examples of Applications Since the LX3V 2TC BD does not have offset and gain functions if it needs for the values out of the standard specifications Additional programming orders will be needed to multiply or divide the converted value Caution Since the use of additional programming orders the converted precision and resolution of the analog Set CH1...

Страница 6: ...hermocouple input mode In Thermocouple input mode LX3V 2TC BD covert an analog value to a digital value in degrees Celsius If in the program is Fahrenheit as a unit it needs to be converted to Celsius value Fahrenheit and Celsius conversion formula Fahrenheit Celsius 9 5 32 the unit is 0 1 D10 D8112 9 D12 D10 5 D0 D12 320 D0 D8112 9 5 320 ...