8.2

 

TORCH LOADING 

 

WARNING! 

Make sure the torch in use is correctly sized in relation to the welding current required and for the available and selected cooling type. This 

prevents the risk of burns to which the operator is potentially exposed, potential faults, and irreversible damage to the torch and the system. 

If a torch is installed or replaced while the unit is running, the circuit of the newly installed must be filled with coolant to avoid the risk of damage 

to the torch in the case of high voltage arc strikes without any liquid in the circuit. 

 
Power-up with operation of the cooler set to "ON" or "AUTO" mode 

  AL. COO. The message appears on the following displays: D1-D2 

(any)

 

  Press the button or torch trigger to repeat the checking procedure for an additional 15 seconds. 

 

 

If the problem persists rectify the cause of the alarm. 

 
Power-up with operation of the cooler set to "OFF" 

 

Operation of the cooler and the cooler alarm are disabled. 

  Welding is performed without liquid cooling of the torch. 

 
Torch change-over with operation of the cooler set to "AUTO" 

Press and release the torch trigger. 

  This serves to start the cooler for 15 seconds to fill the torch cooling circuit. 

9

 

ALARMS MANAGEMENT 

 

This LED illuminates if an incorrect operating condition occurs. 

 

An alarm message appears on the following display: D2 

Tab. 4 - Alarm messages 

MESSAGE 

MEANING 

EVENT 

CHECKS 

AL. HEA. 

Overheating alarm 
Indicates tripping of the welding power 
source thermal protection. 
Leave the unit running so that the 
overheated components cool as rapidly 
as possible. 
When the unit has cooled, the welding 
power source will reset automatically. 

All functions disabled. 
Exceptions: 
-

 

cooling fan. 

-

 

cooler (if switched on). 

-

 

Make sure that the power required by the 
welding process is lower than the maximum 
rated power output. 

-

 

Check that the operating conditions are in 
compliance with the welding power source data 
plate specifications. 

-

 

Check for the presence of adequate air 
circulation around the welding power source. 

AL. COO. 

Cooler alarm 
Indicates insufficient pressure in the torch 
liquid cooling circuit. 

All functions disabled. 
Exceptions: 
-

 

cooling fan. 

The alarm message persists on the display until the first operation is 
performed onthe user interface. 
Cooler ON: the alarm is signalled as long as the unit alarm is active 
and the cooler presence signal persists. 
Cooler OFF: the alarm is never signalled, irrespective of the 
circumstances. 
Cooler AUTO: the alarm is signalled at the times in which the unit is 
running; the alarm signal occurs as long as the unit presence signal 
persists. 

-

 

Check that the connection to the cooler is 
correct. 

-

 

Check that the O/I switch is set to I and that it 
illuminates when the pump is running. 

-

 

Check that the cooler is filled with coolant. 

-

 

Check that the cooling circuit is liquid tight, 
notably the torch hoses and the internal 
connections of the cooler. 

Err. C0 
Err. C1 
Err. C2 
Err. C4 
Err. C11 
Err. C12 

CAN BUS Communication Alarm 
Indicates the presence of problems in 
data communication between the power 
source and wire feeder. 
When the unit has cooled, the welding 
power source will reset automatically. 
Exit the alarm state by performing one of 
the following actions: 
Switch the power source off. 

All functions disabled. 
Exceptions: 
-

 

cooling fan. 

-

 

cooler (if switched on).

 

-

 

Check that the connecting cable between 
power source and wire feeder is intact and 
make sure the connectors are securely 
tightened. 

Err. C69 

Software Incompatibility Alarm 
It triggers when the WF-107 software 
release is incompatible with the power 
source. 

All functions disabled. 
Exceptions: 
-

 

cooling fan. 

-

 

cooler (if switched on). 

-

 

In this event, update the software of the power 
source. 

 

Содержание WF-107

Страница 1: ...0001 1260 10 07 2017 v2 14 ENGLISH WECO srl Via S Antonio 22 BELVEDERE 36056 TEZZE SUL BRENTA VICENZA ITALY Tel 39 0424 561943 Fax 39 0424 561944 www weco it E mail info weco it WF 107 Instruction ma...

Страница 2: ...Cod 006 0001 1260 10 07 2017 v2 14 ENGLISH WF 107 2 32...

Страница 3: ...feed rate 16 Welding current 16 Thickness 16 Programs 16 Time On 16 Time Off 16 Hot Start 16 Crater Filler 16 3 Levels Slope 16 Soft Start 16 Motor Slope 16 Bourn Back 16 Post gas time 16 Pre gas tim...

Страница 4: ...ntifies a reference to a chapter of the manual This symbol accompanies important information concerning the execution of the relevant operations Wire feeder WF 107 is designed for connection to a powe...

Страница 5: ...lding power source 5 Connect the power supply cable of the cooling unit to the auxiliary power socket on the power source 6 Connect the MIG MAG torch coolant outlet and return hoses to the coolant fit...

Страница 6: ...rolls are suitable for the wire gauge Errore L origine riferimento non stata trovata Errore origine riferimento non stata trovata Thediameter of the roll groovemust be compatible with the diameter of...

Страница 7: ...07 2017 v2 14 ENGLISH 0 7 32 9 Refit the protective cover 10 Set the welding power source ON OFF switch to I unit powered 11 Feed the wire through the torch until it protrudes from the tip pressing bu...

Страница 8: ...MINUTE Illuminates together with the following LED The value appears on the following display D1 L8 Illuminates to show a value in the following unit of measurement AMPERES The value appears on the f...

Страница 9: ...seconds to gain access to the JOB save delete menu 12 JOBS MANAGEMENT S5 This button selects the torch trigger procedure S6 This button selects the welding mode E1 Data setting The encoder adjusts th...

Страница 10: ...ACTIONS rEC FAC The message appears on the following displays D1 D2 Exit without confirmation Press any button except S4 This action will automatically close the menu Exit with confirmation S4 Press t...

Страница 11: ...ON Aut Aut on rC REMOTE CONTROLLER SELECTION oFF oFF 06 oFF No control 03 n 1 potentiometer 04 n 2 potentiometers 05 n 1 UP DOWN 06 n 2 UP DOWN LoC ADJUSTMENTS BLOCK SELECTION oFF oFF 3 oFF All adjust...

Страница 12: ...re button S5 Display of main welding parameters button S1 Arc correction encoder E2 Wire insertion button S2 Gas test button S3 Arc correction Potentiometer Pot2 Arc correction UP DOWN lever 2 2 Selec...

Страница 13: ...sure that the power required by the welding process is lower than the maximum rated power output Check that the operating conditions are in compliance with the welding power source data plate specifi...

Страница 14: ...igger procedure 4T or 3L the alarm mutes automatically after 5 seconds Exit the alarm state by performing one of the following actions press any button switch the power source off Check that the progr...

Страница 15: ...rammed wire feed rate In Synergic welding the optimal soft start value indicated with SYN varies in general with variations of the synergic parameters In Synergic welding if the value soft start SYN i...

Страница 16: ...the unit have been enabled or set The table shows the settings required to enable each parameter always available 1 not enabled with manual program P0 MENU MODE PROCEDURE PARAMETER Working voltage 1...

Страница 17: ...1 5 m min 5 0 m min 22 0 m min MIG MAG WELDING CURRENT Syn 1 THICKNESS Syn 1 PROGRAMS P0 P0 P34 WORKING VOLTAGE 10 0 V 20 0 V 40 0 V WELDING INDUCTANCE 0 255 Tab 6 Programmed synergic curves WIRE DIA...

Страница 18: ...00 S 3L 3 LEVELS SLOPE 0 1 s 0 5 s 10 0 s S S SOFT START 10 30 100 1 SLO MOTOR SLOPE 0 ms 40 ms 200 ms 1 b b BOURN BACK 0 ms 16 ms 200 ms 1 11 1 3 MIG MAG PARAMETERS SETTING GAS MENU S3 Hold down the...

Страница 19: ...n is available when welding mode is not active S4 Press and release the button LO J xx Only when the jobs have been uploaded the message is shown on the following displays D1 D2 xx number of the lates...

Страница 20: ...ld completion procedure Gas flow continues until the torch trigger is released 5 Release 4T the torch trigger to start the post gas procedure adjustable time 13 3 3 LEVEL MIG MAG WELDING 1 Bring the t...

Страница 21: ...L x D x H 245 x 670 x 470 mm Weight 21 5 kg Protection rating IP23 Maximum gas pressure 0 5 MPa 5 bar MIG MAG welding voltage 14 2 V 29 0 V Motor speed 1 5 22 0 m min Wire spool dimensions weight 200...

Страница 22: ...Cod 006 0001 1260 10 07 2017 v2 14 ENGLISH WF 107 22 32 15 SPARE PARTS 15 1 WF 107...

Страница 23: ...PLATE 26 011 0014 0073 FIXING CABLE BUNDLE PLATE 27 011 0000 0761 COVER PLATE 28 018 0002 0004 QUICK CLUTCH 29 022 0002 0177 FRONT REMOTE LOGIC CABLE 30 016 5001 3040 SLEEVE HOSE ADAPTER FOR RUBBER H...

Страница 24: ...Cod 006 0001 1260 10 07 2017 v2 14 ENGLISH WF 107 24 32 15 2 WIRE FEEDER MOTOR...

Страница 25: ...ED ROLL 12 002 0000 0322 INTERNAL PROTECTION PLATE 13 002 0000 0305 RETAINING SCREW M4 14 002 0000 0304 SCREW M4x10 15 002 0000 0294 INTERMEDIATE GUIDE 16 002 0000 0324 SCREW M5x10 17 002 0000 0297 IN...

Страница 26: ...1 0 1 2 002 0000 0143 1 2 1 6 002 0000 0149 1 0 1 2 VK shape 002 0000 0150 1 2 1 6 002 0000 0151 2 4 3 2 002 0000 0144 0 8 1 0 U shape Aluminium wire 002 0000 0145 1 0 1 2 002 0000 0146 1 2 1 6 002 00...

Страница 27: ...WF 107 Cod 006 0001 1260 10 07 2017 v2 14 ENGLISH 0 27 32 16 ELECTRICAL DIAGRAM 16 1 WF 107...

Страница 28: ...Cod 006 0001 1260 10 07 2017 v2 14 ENGLISH WF 107 28 32 16 2 CAVO 320 MSR WF 107...

Страница 29: ...V a c In C AN1 5 V 0 5 V a c In D GND GND Out E D1 IN 0 5 V d c In F AN2 10 V 0 10 V a c In G D3 OUT 0 5 V d c Out H AN1 10 V 0 10 V a c In I D2 IN 0 5 V d c In J RC Not used K Not used L Not used M N...

Страница 30: ...Cod 006 0001 1260 10 07 2017 v2 14 ENGLISH WF 107 30 32 16 3 3 RC05 ELECTRICAL DIAGRAM 16 3 4 RC06 ELECTRICAL DIAGRAM 16 4 PUSH PULL OPTIONAL Pin Name Voltage 1 0 V 3 42 V d c...

Страница 31: ...WF 107 Cod 006 0001 1260 10 07 2017 v2 14 ENGLISH 0 31 32...

Страница 32: ...Cod 006 0001 1260 10 07 2017 v2 14 ENGLISH WF 107 32 32...