WeCo - HeSU UNIVERSAL MODEL 5K3 UNIVERSAL STACKABLE
HeSU 5K3-R20 STACKABLE * HIGH CURRENT V_2.00_2019
Pag. 36
MULTI CLUSTER CAN HUB FOR HIGH CAPACITY AND
HIGH CURRENT CONFIGURATION
REQUIRED IF MORE THAN 1 CLUSTER
BMU BMS COMBINER
We-HUB
SEE THE POWER/CURRENT CONFIGURATION BELOW
EACH BATTERY PACK AND EACH CLUSTER MUST HAVE THE SAME SOC %
ABOVE 120A MUST USE THE BUS BAR PROVIDED BY WECO
(Order Ref. -STK 5K3-300)
EACH CLUSTER MUST HAVE THE SAME NUMBER OF BATTERY PACKS
This BMS BMU Master Hub is mandatory when more than one cluster is connected on a
common bus bar.