![Weco Discovery 221AC/DC Evo Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/weco/discovery-221ac-dc-evo/discovery-221ac-dc-evo_instruction-manual_949506011.webp)
WELD THE WORLD
Cod. 006.0001.2000
19/07/2018 V.2.0
Discovery 221AC/DC Evo
Discovery 300AC/DC Evo
11
ENGLISH
CODE
SYMBOL
DESCRIPTION
L12
This LED illuminates to show that the following welding mode is selected: CONTINUOUS DC
TIG
L13
AC
AC
This LED illuminates to show that the following welding mode is selected: CONTINUOUS AC
TIG
L14
SYN
This LED illuminates to show that the following welding mode is selected: SYNERGIC PULSED
DC TIG
When this is on, it means that the synergic mode is active and that the operator can set just the
welding current while the other parameters are automatically regulated by the machine. The
synergy is optimised for angle welding.
L15
This LED illuminates to show that the following welding mode is selected: PULSED DC TIG
L16
AC
AC
This LED illuminates to show that the following welding mode is selected: PULSED AC TIG
S1
DC TIG mode: Press the button to select the DC TIG special functions.
Possible choices: Q-START - DYNAMIC ARC - MULTI TACK - ELECTRODE DIAMETER
AC TIG mode: Press the button to select AC TIG special functions.
Possible choices: MIX AC - EXTRA FUSION - AC FREQUENCY – AC BALANCE - ELECTRO
-
DE DIAMETER
S2
Press the button to access the JOB MENU.
S3
AC TIG mode / DC TIG mode: This button selects the torch trigger procedure.
S4
This button selects the welding mode.
E1/S5
Menu
Menu
-Keep the button pressed while powering on the power source: the button opens the SET-UP
menu.
-Press and release: the button selects the first level menu parameters.
-Hold down for 3 seconds: the button opens the second level menu. When in the menu, press
and release the button to select the parameters.
-Data setting: The encoder sets the value of the selected parameter.
-During the welding operations: The encoder sets the value of the following parameter: WEL
-
DING CURRENT
USB
Port provided to connect a USB memory stick to export/import JOBs.
D1
IData setting: The display shows the parameter to be set, its value and the graphic symbol
associated to it.
Welding: The display shows the effective amperes value during welding.
Antwerpsesteenweg 949 9041 Gent - Oostakker
[email protected]
www.welda.be
T
+32 (0)9 355 74 26
F
+32 (0)9 355 92 01