![Weco cad III Скачать руководство пользователя страница 38](http://html1.mh-extra.com/html/weco/cad-iii/cad-iii_operation-manual_949489038.webp)
38
8.2 Error messages
Error
message
Message meaning
Correction
E 01
The entered drilling coordinate lies
outside the allowable range.
Press <C> key – Select drilling
coordinate inside the allowable range.
E 02
The distance of the drilling coordinate
is less than 1 mm to the edge.
Press <C> key – this message is to
be understood as warning.
E 03
The distance between 2 drill holes is
less than 1 mm.
Press <C> key – this message is to
be understood as warning.
E 05
The X or Y decentration value is too
high, the decentration point is located
outside the form.
Press <C> key – enter a smaller /
higher value.
E 06
Decentration values X or Y in menu
1D are zero.
Press <C> key – enter correct
decentration value.
E 07
Timeout - Time error when requesting
a form out of the CAD2000 memory.
Press <C> key – repeat entry.
No form available.
Press <C> key – Trace form, Repeat
entry.
After entry of the form number the
<ENTER> key was not pressed
Press <C> key, repeat entry,
Press <ENTER> key
E 08
Upper drilling limit reached (menu 4).
Press <C> key – change entry using
the cursor keys.
E 09
Lower drilling limit reached (menu 4).
Press <C> key – change entry using
the cursor keys.
E 10
The drill hole does not lie in the
represented graphic area (menu 4).
Press <C> key – change entry using
the cursor keys.
E 15
Transmitted sides 1 and 3 are not
equal.
Press <C> key – request form again.
E 16
The value for m is smaller than the
total of the A measurement and the
DBL. This results in a negative DBL
value.
Press <C> key, enter correct value.
E 18
Use small clamping piece.
Press <C> key (menu 1-3).
Press <C> key – change entry using
the cursor keys (menu 4).
E 40
No CL connection available.
Press <C> key – check cabel
connection, switch on master.
E 41
Transmission error while transmitting
a data set.
Check CL-address for conflicts,
change as necessary.
E 42
Transmission error while receiving a
data set.
Check CL-address for conflicts,
change as necessary.