WARNING: Air holes must be provided in the
structure at the top and bottom to provide
ventilation in the event of a gas leak.
Air holes can be located in a low visibility area and should
be protected by screening material to prevent rodents and
insects from entering the structure. Air holes will also help
dry moisture.
Vieluxe
®
cabinet vents (#36312) are available from your
dealer or call Vieluxe
®
Customer Service at
1-866-VIELUXE.
■
Cross ventilation must be incorporated in the
supporting structure. We recommend a minimum of
100 square inches of venting per side.
■
Vents should be on two sides of the structure.
The above drawings are for reference only.
■
Location of the vents should be from the center,
outward.
■
Locate the vents at both the bottom of the structure
and at the top of the structure.
■
The bottom vents should be as close to ground level
as possible. Make sure the vent area is not blocked
by interior supports of the structure.
■
We recommend vents with screens.
■
Access doors to the structure are not considered vents.
■
Clean the vents periodically.
DANGER: Failure to follow recommended minimum
venting instructions can cause gas to collect in the
structure in the event of a gas leak. This may result
in a fire or an explosion which can cause serious
bodily injury or death, and damage to property.
Note: These drawings are only a reference.