10
WWW.WEBER.COM
®
2
7
1
5
6
A
A
* The grill illustrated may have
slight differences than the
model purchased.
CHECK:
1)
Main gas line to manifold connection.
2)
Rotisserie (I.R. Burner) gas line connection.
3)
Bulkhead and gas supply hose connection.
4)
Corregated gas line to bulkhead connection.
WARNING: If there is a leak at connection (1, 2, 3, or 4),
retighten the fitting with a wrench and recheck for leaks with
soap and water solution.
If a leak persists after re-tightening the fitting, turn off the gas.
DO NOT OPERATE THE GRILL. Contact the Customer Service
Representative in your area using the contact information on
our web site. Log onto www.weber.com
®
.
5)
Hose to regulator connection.
6)
Regulator to cylinder connection.
7)
Valves to manifold connections.
WARNING: If there is a leak at connections (5, 6 or 7 ), turn
off the gas. DO NOT OPERATE THE GRILL. Contact the
Customer Service Representative in your area using the
contact information on our web site.
Log onto www.weber.com
®
.
When leak checks are complete, turn gas supply off at the source and rinse connections
with water.
REINSTALL CONTROL PANEL
Parts required: control panel, screws and burner control knobs.
Hook the top edge of the control panel onto the control panel brackets on either side of
the front of the cooking box.
Line up screws with screw holes on both the control panel bracket and the frame.
Tighten screws.
Place corresponding control knobs onto the valve stems.
GAS INSTRUCTIONS
4
3
A
Содержание Summit 43143
Страница 4: ...4 WWW WEBER COM S440_LP_US EXPLODED VIEW S 440...
Страница 25: ...25 WWW WEBER COM 25...