SONIC DIGITAL HS MD/MFD
Description
17
5.2.2
PIN assignment, mains connection
PIN
Designation
Function
1
L
230 V AC (L)
2
N
230 V AC (N)
3
PE
PE conductor (PE)
Table 3: PIN assignment, mains connection
5.2.3
PIN assignment, converter connection
Part of the converter connection
Function
Shield
Negative connection on the converter
Inner conductor
Positive connection on the converter
Table 4: PIN assignment, converter connection
DANGER!
Voltage is applied to the converter connection during operation
(ultrasonic output):
Risk of serious injury due to electrical voltage.
Do not touch!
Switch off the generator and disconnect it from the mains
before unplugging the converter connection.
In the event of an emergency, press the EMERGENCY STOP button
(de-energise) and perform any first aid as necessary.
NOTE
§
Only ever use the connection cable
provided
or screened transducer connection cables (coaxial cables)
with an internal conductor diameter of
0.5 mm² to connect
the converter.
Always connect the cable's PE conductor to the shield on the
converter connection.