6 SRV
650
prior to maintenance and repair work
Only use
original Weber spare parts
for maintenance or repair work to ensure reliable and safe
operation.
For repair, maintenance, or inspection work the engine of the tamper must be safeguarded against
unintentional starting.
All pressurized lines, particularly hydraulic lines and lines of the injection system of the drive motor
must be depressurized before performing maintenance or repair tasks.
For maintenance and repair tasks the tamper must be placed on a level and stable substrate and
must be secured from rolling off or tipping over.
Heavy components and assemblies must be secured to and lifted by hoisting machines that can
bear their weight when they are replaced. Ensure that no hazard is caused by raising components or
assemblies.
Do not position yourself or work under suspended loads.
Operation under difficult conditions
Never inhale the exhaust gas; it contains carbon monoxide, a colorless and odorless gas that
is extremely hazardous, which, if inhaled even briefly, can cause unconsciousness and death.
Therefore, never operate the engines in enclosed areas or in areas that are poorly ventilated
(tunnels, caves, etc.). Exercise particular caution when operating the engine in the vicinity of
people and livestock.
Adjusting tasks, maintenance tasks, and inspection tasks must be carried out on schedule as
specified in this operating and maintenance manual. These activities should only be executed by
trained personnel.
Operation
Prior to starting work the owner of the tamper must be familiar with the work environment. The
working environment includes obstacles in the work and traffic area, the bearing capacity of the
ground, as well as the necessary safeguarding of the construction site in the area adjacent to public
traffic; and it also includes compliance with traffic regulations.
The tamper should only be operated when the protective fixtures are mounted. The protective fixtures
must all be in functional condition.
At least once per shift the tamper must be checked for apparent defects. If there are apparent defects
then operation of the tamper must be stopped immediately and the responsible person must be
informed. Prior to restarting, tamper malfunctions that have occurred must be corrected.
If lubricating oils and fuel come into contact with skin, they can cause skin cancer. Upon contact
with the skin, clean affected skin with suitable cleaning agent without delay.