20
CR 9-II MDM
1
3
2
4
5
Checking the battery / acid level
Battery acid is extremely caustic. Protect hands and
eyes with suitable protective goggles and gloves.
Remove the cover cap (1).
Check the acid level; if it is too low top off with distilled
water up to the max. mark.
Changing the oil in the exciter
Remove the oil drain plug (2) and drain oil.
Select collection vessels large enough to prevent oil
from spilling onto the ground. Dispose of waste oil
in an environmentally friendly manner (regulation on
waste oils).
Wipe up / off oil slick and oil residue and dispose of
fuel-soaked cleaning cloths in an environmentally
responsible manner.
To fill – tilt the machine slightly and fill with fresh oil through
the drain opening in accordance with the fill level table.
The fuse is located on the battery, behind the dashboard
carrier.
Changing the fuse
Remove the protective cap (3) of the fuse holder.
Insert new fuses with rated values of 20 A / 10 A.
Checking the V-belt
Remove the right side cover (4) as viewed from the guide bar.
Check the V-belt (5) for cracks, damaged flanks, and wear.
If there is excessive wear – replace the V-belt as specified
in the repair manual.