Thermo 230/231/300/301/350
To install the circulating pump
49
5.4.
Aquavent 6000 S circulating pump
NOTE:
When connecting the circulating pump is must be ensured that the
volume flow does not drop below 1800 l/h !
Fig. 20: Aquavent 6000 S circulating pump
Installation position
0-90°
Sw+
Br-
284
53
31
110
500
32
60
115
24
85
97,5
122,5
6,5
63
38
38
23
180,5
100
*
90°
* Clamping area of the stand clamp
Fig. 21: Hole pattern for the stand for the Aquavent 6000 S
circulating pump
Fig. 22: Delivery rate and flow resistance
Aquavent 6000 S circulating pump
Delivery rate
(with water at 20°C)
Flow resistance
(with the pump stopped)
Th23_EA_degbfr_g.book Seite 49 Dienstag, 15. Februar 2005 2:03 14