Technical data
122
20.2. Technical data
Heater
Operation
DUAL TOP RHA 100
DUAL TOP RHA 101
DUAL TOP RHA 102
Type approval
heater:
EMC:
e1 00 0195
e1 03 5000
Model Air
heater
with
evaporator burner
Air heater with evaporator burner and electric heating device
Heat output
diesel
electric
Control range
1.5 to 6.0 kW
-
1.5 to 6.0 kW
0.6 / 1.2 kW
1.5 to 6.0 kW
1.0 / 2.0 kW
Fuel
Diesel, DIN EN 590
Fuel consumption
Control range
0.17 to 0.65 l/h
Rated voltage
12 V
Operating voltage range
10.5 to 15 V
Current input at 12 V
Summer operation
Winter operation, heating
and hot water
Stand-by
< 1 A
0.5 to 7 A
0.001 A
Rated power consumption
Control range
15 to 65 W (EN 1646)
Max. ambient temperature:
Heater:
- Operation
- Storage
Control Panel:
- Operation
- Storage
-30 to +50 °C
-40 to +85 °C
-30 to +75 °C
-40 to +85 °C
-30 to +50 °C
-40 to +85 °C
-25 to +50 °C
-40 to +85 °C
Max. altitude (guaranteed function)
2,200 m
Adjustment range for interior temperature Control range
+5 to +35 °C
Delivery rate for hot air (free blowing with-
out warm-air duct)
Maximum >
200
m
3
/h
CO
2
in exhaust gas (permitted function
range)
2 kW
6 kW
5.0 to 8.0
9.0 to 13
Water content
11 l
Water system pressure
max. 3.5 bar