Code
Description
Possible
Default
Recommended
Chiller
CPAC AirH.
b
Set security CODE.
00 = No access code
required. Possible to
set at 01 - 99.
If security code is set
active, only the
temperature set point
and blower speed
settings can be
changed.
64 Chiller /
CPAC
00 Air handler
●
●
●
c
Dehumidifying heating
run time.
Min. 1 / Max. 99
minutes
Recommended:
Chiller 40 in winter
and 15 in summer
times.
CPAC 30 in winter and
10 in summer times.
Set 45 in tropical
conditions with hot
sea-water.
01 CPAC /
Air handler
●
●
●
d
Dehumidifying cooling
run time.
Min. 01 / Max. 99
minutes
Recommended:
Chiller 20 in winter
and 45 in summer
times.
CPAC 15 in winter and
30 in summer times.
Set 1 in tropical
conditions with hot
sea-water.
01 CPAC / Air
handler
●
●
●