Electrical connections
59
12
Electrical connections
All the cables that are not required must be insulated.
NOTE:
If the combination or standard timer is used, a touch-sensitive switch
may be installed in the sleeping section to act as a remote control and
improved convenience. The connections must be made as shown in the
circuit diagrams in Figures 31 and 32, 34 or 35.
The electrical connection is made as shown in the system circuit
diagram (Figures 30, 31, 32, 33, 34, 35 or 36).
12.1. Connection for installing the heater in a hazchem vehicle
(ADR)
To install the Air Top 2000 S-D heater in hazchem vehicles, the
requirements of ADR/RID part 9 para. 9.2.4.7 – Combustion heating
systems, must also be satisfied. The electrical connection is made as
shown in the circuit diagram, Figs. 33, 34 or 35. On vehicles without a
power take-off the electrical connection must be made as shown in the
system wiring diagram in Figure 36.
NOTE:
The switch S4 must be installed in such a way that a positive potential
is connected to appropriate input of the control module when a pumping
device is switched on.
IMPORTANT
All ADR functions are ineffective if there is no earth at control unit input
X11/2 when the system is switched on. The control unit continues to run
briefly for 20 seconds and then switches to "fault lock-out" operating
mode when a positive voltage is connected to control unit input X11/2
(auxiliary power take-off on) or the engine is switched off.
IMPORTANT
In accordance with the regulations of the act governing the road/rail
haulage of hazardous materials, heaters are only allowed to be taken
into service with a special manually operated switch fitted in the cab.
If the system is equipped with a combination or standard clock, ensure
that contact 4 on the combination or standard clock remains free. The
heater can then only be taken into service using the immediate heat
button.
The use of other timers in ADR vehicles is not permitted.
12.2. Heater connection
To connect the wiring harness, remove the control unit cover on the
heater and connected the wiring harness plug to the control unit.
NOTE:
Raise the control unit cover on both sides using a blunt blade (Figure 23
arrows).
Fig 23:
To remove the control unit cover