background image

1

http://support.weathermatic.com

1.0 Installing the Aircard

1.0 Installing the SmartLink Flow Aircard

1. 

Verify that the version of SmartLine controller you are 
connecting this Aircard to is compatible. This can be 
done through the “Advanced Menu” of the SmartLine 
controller. Only versions 3.1 and higher are compatible. 

2.  Remove the SmartLink Flow Aircard’s accessory bag 

from the box. This contains the mounting screws, and 
antenna.  

3.  Before mounting to the wall, screw the 

antenna firmly into the bottom of the 
Aircard. 

4.  There are 2 cables leaving the bottom 

of the Aircard. Locate the cable on 
the left with the clear RJ-11 connector 
on the end. This is the Aircard cable 
and will need to be run up through the 
bottom of the SmartLine controller 
case. You may need to widen an 
existing hole using a drill or punch out 
the area indicated on the bottom. 

5.  Plug the Aircard cable into the RJ-11 

jack located inside the controller. If the controller has 
two RJ-11 jacks (SL4800), either jack will work. The jack 
is located in the upper right area, and is black. Ensure it 
is plugged in completely. 

6.  Verify that all of the nearby cables are put neatly 

in place, which will enable the panel door to close 
completely.

7.  The Aircard status LED will flash rapidly green until 

it cycles through the 4 status positions. This will last 
approximately 15-30 seconds. 

8.  Take note that on the outside of the Aircard’s box and 

on the right side of the Aircard itself is a label printed 
with the 19- digit ID number. 
This is specific to this Aircard 
and will be needed to activate 
and register your Aircard on the 
SmartLink Network.

9.  If you have not yet activated and registered your 

Aircard, see Step 2 – Setting up your SmartLink 
Network Account to activate. You will need the 19-digit 
ID number. 

10.  If you have already activated the Aircard, the Aircard 

status LED will remain a solid green light once 
communication is established. If, after activation on 
the SmartLink Network, the status LED continues to 
flash red, please contact the Help Desk. http://support.
weathermatic.com

LTE

Содержание SmartLink SL-AIRCARDFLOW

Страница 1: ...SmartLink Flow Aircard SL AIRCARDFLOW Owner s Manual LTE Commercial Wireless ...

Страница 2: ...c com Telephone 888 484 3776 Scan with smartphone to go to web based help www weathermatic com Introduction If you wish to install and activate this SmartLink Flow Aircard before the SLFSI Flow Sensor is installed or accessible only complete Sections 1 and 2 Complete Section 3 once you re ready to move forward with wiring the flow sensor to the Aircard and completing the SmartLink Network Flow set...

Страница 3: ...r If the controller has two RJ 11 jacks SL4800 either jack will work The jack is located in the upper right area and is black Ensure it is plugged in completely 6 Verify that all of the nearby cables are put neatly in place which will enable the panel door to close completely 7 The Aircard status LED will flash rapidly green until it cycles through the 4 status positions This will last approximate...

Страница 4: ...ed areas marked with an asterisk Note Company Name is required If creating a personal account use your name in place of the company name 2 Once logged in you will be taken to the Sites page Note Sites are like folders that contain the SmartLine or ProLine controller s 3 You can begin by adding a new Site or add the new SmartLine controller to an existing Site 4 To add a New Site for the controller...

Страница 5: ...tivated Once activated the Aircard can be moved and connected to any SmartLine controller Version 3 1 or higher If the Aircard has yet to be installed please see 1 0 Installing the SmartLink Flow Aircard 14 If any errors occur after installation and activation on the SmartLink Network see Step 5 0 Troubleshooting or contact our Help Desk for further assistance 15 Once the Aircard is activated you ...

Страница 6: ...es The Flow Sensor must be installed in accordance with the minimum distances that are shown in the installation diagram 3 Install an adequately sized valve box over the Flow Sensor for proper maintenance access 4 Use P 39 approved underground burial cable from the Flow Sensor to the Aircard mounted next to the controller Maximum wiring distance from sensor to the Aircard is 2000 feet 610m The cab...

Страница 7: ...nce range The entire system will be shut down if it detects two zones in a row reporting flow usage outside of the user defined high low tolerance range This indicates a system mainline break has occurred With a Master Valve installed breaks in the system s mainline will be protected because the Master Valve is turned off when the alert occurs Systems without a Master Valve installed will still re...

Страница 8: ...w Sensor information PPG for other compatible Flow Sensor brands 3 Line Fill Time Choose the length of time in seconds that it takes the main and lateral lines to charge 4 Sample Time Choose interval at which sampling of flow will occur Currently fixed at 60sec subject to change 5 Low Flow Tolerance Set the of low flow tolerance to be globally applied to all zones This is overridden if a Low Flow ...

Страница 9: ... 0GPM in these columns flow has not been learned SmartLink Network Global Flow Settings Zone Flow Settings and Operation 4 0 Learning Flow for the First Time a Once the Flow Settings have been applied run through a complete program cycle You can run a manual cycle or schedule a runtime to avoid watering during restricted times Make sure though that every zone has run b Current Average is calculate...

Страница 10: ...nk Flow Aircard to automatically set the Low High Flow Limits by using the Low High Flow Tolerance settings you entered earlier in the Global Flow Settings This will calculate the Low High Flow Limits from the Running Average automatically For example if a zone s Running Average is 100GPM and the Global Low High Tolerance was set to 25 the zone s Low and High Flow Limits would be set to 75GPM and ...

Страница 11: ...r it is within For more information regarding Reports click the Help tab at the top of the page 5 0 Troubleshooting Controller not supported The controller identifies as firmware version other than 3 10 or 3 13 Only 3 10 and higher are compatible and supported Contact distributor to upgrade Could not connect The connection timed out Usually this is seen when the Aircard is unplugged or requires a ...

Страница 12: ...ADSLAC MN FLOW RevC Commercial Wireless ...

Отзывы: