> 5.23.3.6 LEAK
DET
A settable value that determines when the controller will produce a Leak
Detect fault.
> 5.23.3.7 LOW
LMT
The lowest ow value the controller can sense without producing a fault.
> 5.23.3.8 HIGH
LMT
The highest ow value the controller can sense without producing a fault.
5.23.4 TOT
FLOW
Shows the daily total ow for each zone. Can scroll through each zone for a 7-
day history.
5.23.5 LOW PK
Shows the lowest ow value for each individual zone, can scroll through each
zone for a 7-day history.
5.24 SLW
5.24.1
RAIN
The rain selection is on/o toggle to override the SLW sensor feature for selected zones.
Factory default is ON for all zones.
5.24.2
FREEZE
The freeze selection is on/o toggle to override the SLW freeze sensor feature for
selected zones. Factory default is ON for all zones.
5.24.3
DELAY
This feature allows the user to adjust the factory set 48 hour watering delay that will
occur after a rain event shutdown if you are using an SLW Weather Sensor. To eliminate
the delay or to reduce or increase the factory default hours, turn the dial to Advanced
Menu and use an UP and DOWN button to select SLW DLY. Press the NEXT button and
48 hours will show in the display. Use the UP and DOWN buttons to eliminate the delay
or to select a di erent number of hours (0–99 hours). Note: The SLW DLY begins after
the SLW rain sensor has reset following a rain event. Accumulation of new water de cits
will not begin until after the SLW DLY has cleared.
5.25 RAIN DLY
The rain delay feature allows user to globally suspend watering operations for all programs for a selected
number of days in either the BASIC or SMART watering modes.
Use UP or DOWN buttons to select 1 to 14 days for watering suspension. The watering blackout will
automatically be cleared from the SmartLine® controller after the assigned days have expired and watering
will resume at the next available start time. SMART watering de cits will reset at zero and will not resume
accumulation until the delay has ended.
5.26 SKIP CUR
You can increase the skip circuit threshold here. Some accessories, like pump start relays, In rush currents
exceed the factory setting of 1.0 Amp for SL800 and 1.5A for all other controllers. The maximum setting is
2.5A.
5.27 REVIEW