5.0  Advanced Menu

6.0 Troubleshooting

6.1 Total Reset Procedure For The ProLine® controller

A total reset will clear all programming data in the ProLine® 

controller. All settings will return to factory defaults. 
For all ProLine® models except PL800:
•  Turn dial to Advanced Menu.
•  While pressing the UP arrow button, use an open paper clip or 

ballpoint pen to push in the Reset switch located on the back of 

the operating panel. Release the reset button while continuing to 

press and hold the UP arrow button.

•  Once the display shows CLEARING, release the UP arrow button.
•  Reprogram ProLine® controller.
For the PL800:
•  Unplug the power supply on the side of the PL800.
•  Turn dial to Advanced Menu.
•  While continually holding down on the UP arrow button, reapply 

the power connection to the PL800.

•  The display will read “CLEARING” to verify that the Reset is 

complete. Re-enter your controller settings.

6.2 Watering Cycle Pause Functions

ProLine

®

 controllers will “pause” watering cycles in response to 

certain sensor readings or program settings in the controller. 

Pauses are a normal function of the controller. If a watering pause 

occurs, the reason will be shown on the controller’s display. The 

table below provides a more detailed description of each message.

LANGUAGE

LED Color

SENSOR 

LED Color

Display 

Message

Reason

Red

Controller dial is set 

to OFF

Green

Red

RAIN

Rain sensor disks are 

wet (SLW Only)

Green

Red

FREEZE

Temperature is 37 

degrees F or colder 

(SLW Only)

Green

Red

SENS

Sensor tripped at the 

SEN terminals

Green

Orange

RAIN 

DLY

Irrigation cancelled 

for additional hours in 

SLW DLY (SLW Only)

Orange

Green

Omit-

Time

Cycle paused for omit 

hours set

Orange

Green

SOAK

Zone waiting for soak 

time out

Orange

Green

ZONE 

DLY

Waiting for next zone 

valve to open

Orange

Green

PAUSE

Waiting for MVP to 

turn on or off

Содержание ProLine 1600 Series

Страница 1: ...MANUAL PROGRAM DOWN ENGLISH ESPAÑOL LANGUAGE SYSTEM OFF ADVANCED MENU RUN MANUAL PROGRAM MULTIMETER VALVE LOCATOR SENSOR OPERATION RUN AND SOAK CYCLES CURRENT TIME DATE PROGRAM START TIMES ZONE RUN TIMES DAYS TO WATER OMIT TIMES DAYS MONTHLY ADJUST MANUAL ZONE MANUAL TEST ON RAIN FREEZE SENSOR OFF ...

Страница 2: ... children or the infirm without supervision Young children should be supervised to insure they do not play with this appliance If the supply cord is damaged it must be replaced by the manufacturer an authorized service agent or a similarly qualified person in order to avoid a hazard U S Patent No 7 406 363 TRADEMARKS Weathermatic ProLine Smart Solutions for the Professional www weathermatic com He...

Страница 3: ...taller For the Weathermatic distributor directory go to www weathermatic com SLM2 2 Zone Module for PL800 only SLM4 4 Zone Module for PL1600 only SLM12 12 Zone Module for PL4800 only RFS5 Wireless rain freeze sensor inch 1 2 3 4 1 4 1 8 ProLine Accessories SL AIRCARD SL AIRCARDFLOW Web based control from PC tablet smartphone Flow management option ...

Страница 4: ...tor 8 4 3 Sensor Operation 8 4 4 Run and Soak Cycles 9 5 0 Advanced Menu 10 5 1 FAULTS 11 5 2 OPEN CIRCUIT FAULT 11 5 3 LANGUAGE 12 5 4 UNITS 12 5 5 DEFAULT 12 5 6 GROW IN 12 5 7 ABOUT 12 5 7 1 MODEL 12 5 7 2 VERSION 13 5 7 3 BUILD 13 5 7 4 SER NUM 13 5 7 5 HW VERSION 13 5 7 6 NUM ZONES 13 5 7 7 EEPROM 13 5 7 8 SLHUB VER 13 5 7 9 SLHUB BLD 13 5 7 10 SLAC B VER 13 5 7 11 SLAC B BLD 13 5 7 12 Z96 TY...

Страница 5: ...GS 16 5 21 4 TOT FLOW 16 5 21 5 LOW PK 16 5 22 SLW 17 5 22 1 RAIN 17 5 22 2 FREEZE 17 5 22 3 DELAY 17 5 23 RAIN DLY 17 5 24 SKIP CUR 17 5 25 REVIEW 17 5 25 1 SLW 17 5 25 2 TOTL RUN 17 5 25 3 CLR TOTL 17 6 0 Troubleshooting 18 6 1 Total Reset Procedure For The ProLine Controller 18 6 2 Watering Cycle Pause Functions 18 6 3 Troubleshooting Guide 19 ...

Страница 6: ...r Program A To view watering days for Program B C or D just press the PGM button Fault Indicator Appears ONLY when a fault is detected Turn dial to Advanced Menu and press NEXT button to view faults Once you turn the dial to Advanced Menu the fault indicator will stop flashing but will continue to appear on the screen until the fault is removed or user clears fault in Advanced Menu If fault is cle...

Страница 7: ...l occur If you move the dial to any position other than RUN or SYSTEM OFF and there is no control panel activity for 30 minutes the controller will return to the RUN mode and the display screen will show the idle default screen or will return to a program in progress that was interrupted Note If a station is running the dial must remain in SYSTEM OFF until the displays returns to the time of day L...

Страница 8: ...e top level menu of the dial position is reached A VALUE CHANGE will be entered in memory any time you 1 move to a different menu or 2 move the programming dial to a different position 2 0 Programming 2 1 Current Time Date Use UP and DOWN arrow buttons to change the flashing value for the hour Scrolling past 12 will automatically change AM PM Remember holding down the UP or DOWN arrow button will ...

Страница 9: ...electable in one minute increments Run times of 1 hour to 9 hours 55 minutes are selectable in 5 minute increments Use UP or DOWN arrow buttons to set flashing time values for each zone If a zone is not to be used set it to OFF Push PGM button to assign zone time in one or more programs Caution If an unused zone is turned on and activates a pump start relay the pump may overheat or cause a pipe to...

Страница 10: ...e the UP or DOWN arrow buttons to select OMIT TIME OMIT DAYS and OMIT DATES You may choose any or all of these omit options If you want a watering blackout for the same period each day select OMIT TIME Then push NEXT A forward arrow indicates the beginning time for the blackout Use UP and DOWN arrow buttons to set beginning time Then push NEXT A reverse arrow indicates the end time for the blackou...

Страница 11: ... run time in any program Any zone without an assigned zone run time will NOT run in the Manual Test Use UP and DOWN arrow buttons to set Manual Test run time The Manual Test can be set to run a minimum of 10 seconds or a maximum of 10 minutes You must return dial to RUN for Manual Test operation to begin 3 0 Manual Start Functions RUN SYSTEM OFF CURRENT TIME DATE PROGRAM START TIMES ZONE RUN TIMES...

Страница 12: ...more than one valve on a zone the ProLine controller will measure total current for the combined valves Battery To check the battery voltage level applies to PL1600 PL4800 only turn dial to Multimeter Outputs will appear on the screen Push the Adjust Value up arrow button one time Battery will appear on the screen Push the Next button once to read battery voltage status A minimum of 7 5V is requir...

Страница 13: ... a Rain shutdown event beyond the short time the Rain sensor is actually wet saving even more water Press the NEXT button at SLW to display DELAY Press NEXT again to display the number of hours the controller will suspend irrigation after the Rain sensor has dried out The factory default is 48 hours RAIN and FREEZE selections work the same as SENSOR described above however allow you to differentia...

Страница 14: ...the controller is OFF Once you have entered in the run time desired press the BACK button The value flashing will be saved After the RUN time has been configured press the UP or DOWN button so that the display reads SOAK Press the NEXT button to alter the SOAK time Use the UP and DOWN buttons to adjust the soak time Selectable times for soaking range from OFF to 2 hours adjustable in 1 minute incr...

Страница 15: ...CATOR SENSOR OPERATION RUN AND SOAK CYCLES RUN SYSTEM OFF CURRENT TIME DATE PROGRAM START TIMES ZONE RUN TIMES DAYS TO WATER OMIT TIMES DAYS SEASONAL ADJUST MANUAL ZONE MANUAL TEST MANUAL PROGRAM MULTIMETER VALVE LOCATOR SENSOR OPERATION RUN AND SOAK CYCLES ADVANCED MENU ADVANCED FUNCTIONS UNITS DEFAULT GROW IN ABOUT MODBUS CLR ALL CLR PGM CON PGM NO NC MV MV ZONE MV ZN DLY MV2 ZONE NUM STRT DS TI...

Страница 16: ...dication can be manually cleared or will be automatically cleared if the short condition goes away and the output turns on successfully SCROLLING FAULT MESSAGE FAULT DESCRIPTION ZONE XX OPEN MV1 OPEN MV2 OPEN OUTPUT OPEN CIRCUIT If a zone has a current draw less than 0 03 Amps a zone open fault is created but operation continues normally The fault can be manually cleared or will automatically clea...

Страница 17: ...ns The display will show RETRIEVE Pressing NEXT one more time will show the CONFIRM prompt press NEXT to proceed or BACK to exit the prompt Pressing NEXT at the CONFIRM prompt will cause the display to read COMPLETE to show that you have successfully restored the program default program to the operating program Press the BACK button any time after the display shows COMPLETE to return to the advanc...

Страница 18: ... the aircard NI is show if this is not installed 5 7 11 SLAC B BLD Displays the build version of the aircard NI is show if this is not installed 5 7 12 Z96 TYPE Displays the decoder manager type if SmartWire equipped 5 7 13 Z96 VERS The display reads Z96 VERS here 5 8 MODBUS 5 8 1 SHORT ADD This displays a static address along with a user programmable address to integrate with third party software...

Страница 19: ...pump start relay the pump may overheat or cause a pipe to burst To prevent operating a pump with no flow dead heading make sure all unused zones are set to OFF 5 14 MV ZN DLY This function allows the user to set a delay time between the opening of the master valve and the opening of the first zone valve as well as a delay between the closing of the last zone valve and the closing of the master val...

Страница 20: ...ime of day on the occurrence of Daylight Saving Time make sure it is turned on in this menu 5 18 2 DS SETUP Your controller is programmed with the a default of starting Daylight Saving Time starting on the second Sunday in March and ending on the first Sunday in November If you would like to adjust these settings you may do so in this menu 5 19 RUN SOAK The purpose of Run Soak is to break up long ...

Страница 21: ... 3 7 LOW LMT The lowest flow value the controller can sense without producing a fault 5 21 3 8 HIGH LMT The highest flow value the controller can sense without producing a fault 5 21 4 TOT FLOW Shows the daily total flow for each zone Can scroll through each zone for a 7 day history 5 21 5 LOW PK Shows the lowest flow value for each individual zone can scroll through each zone for a 7 day history ...

Страница 22: ... SLW 5 25 2 1 LASTCOM This feature records time elapsed since last successful communication between the weather station and control panel 5 25 2 2 BATTERY Check the battery status in your wireless weather station here 5 25 2 TOTL RUN TOTL RUN is the total run time for each zone since the date shown default date in the SmartLine controller is January 1 2000 shown as 01 01 00 You can review TOTL RUN...

Страница 23: ... display will read CLEARING to verify that the Reset is complete Re enter your controller settings 6 2 Watering Cycle Pause Functions ProLine controllers will pause watering cycles in response to certain sensor readings or program settings in the controller Pauses are a normal function of the controller If a watering pause occurs the reason will be shown on the controller s display The table below...

Страница 24: ... Check solenoid s and wiring Display shows zone is running but no sprinklers are operating Water supply to system is shut OFF Turn on water supply to system Valve failure Verify valve operation Open or disconnected wire Run MANUAL TEST as shown Verify FAULT icon is shown display Turn dial to Advanced Menu to determine location of fault Controller keeps repeating a watering cycle Extra start times ...

Страница 25: ...has commenced normal operation Modify settings such as concurrent program start times zone run times to prevent stacking if undesirable Time of day or date not set properly Review set time of day and date Watering days or omit days dates not set properly Review set watering days or omit days dates Run Soak feature has extended watering window Normal operation to allow water infiltration and preven...

Страница 26: ...to SYSTEM OFF Position Turn dial to RUN No zone run time set no daily start time set Program zone run time and daily start time Omit times days are activated Verify omit times days Rain or freeze sensor has stopped watering Sensor LED is red Replace sensor if faulty Select BYPASS mode if desired Reset start time to later in the day to avoid early morning freezing temperatures ...

Страница 27: ... W T F S S M T W T F S S M T W T F S S M T W T F S Odd Even Odd Even Odd Even Odd Even Interval Every ____ days Interval Every ____ days Interval Every ____ days Interval Every ____ days Program Start Times Program Start Times Program Start Times Program Start Times 1 5 1 5 1 5 1 5 2 6 2 6 2 6 2 6 3 7 3 7 3 7 3 7 4 8 4 8 4 8 4 8 Omit Days Date Times Days Dates Times From To ...

Страница 28: ...n Program A Program B Program C Program D Zone Run Time Zone Run Time Zone Run Time Zone Run Time 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Seasonal Adjust PGM Jan Feb Mar Apr May Jun Jul Aug Sept Oct Nov Dec A B C D ...

Страница 29: ...atic com Basic Watering Schedule Zone Location Program A Program B Program C Program D Zone Run Time Zone Run Time Zone Run Time Zone Run Time 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 ...

Страница 30: ......

Страница 31: ...www weathermatic com ...

Страница 32: ...www weathermatic com ADG51_revA ...

Отзывы: