4

ON-OFF / ADVANCED

1-10 V

DALI

BASIC

Anschlussplan

WE-EF Eco Step Dim® Advanced und 

nicht dimmbare Leuchten

SKI

Phase an 

L1

, Neutralleiter an 

N

, Schutzleiter an 

SKII

Phase an 

L1

, Neutralleiter an 

N

WE-EF Eco Step Dim® Basic

SKI

Phase an 

L1

, Steuerphase an 

L2

Neutralleiter an 

N

und Schutzleiter an 

SKII

Phase an 

L1

, Steuerphase an 

L2

, Neutralleiter an 

N

1-10V / DALI

SKI

Phase an 

L1

, Neutralleiter an 

N

, Schutzleiter an 

,

1-10V an 

+

und 

, DALI an 

D

SKII

Phase an 

L1

, Neutralleiter an 

N

1-10V an 

+

und 

, DALI an 

D

Wiring Diagram

WE-EF Eco Step Dim® Advanced  and

non dimmable luminaires

Class I

Phase to 

L1

, Neutral to 

N

and Earthing to 

Class II

Phase to 

L1

, Neutral to 

N

WE-EF Eco Step Dim® Basic

Class I

Phase to 

L1

, Control Phase to 

L2

Neutral to 

N

and Earthing to 

Class II

Phase to 

L1

, Control Phase to 

L2

, Neutral to 

N

1-10V / DALI

Class I

Phase to 

L1

, Neutral to 

N

and Earthing to 

1-10V to 

+

and 

, DALI to 

D

Class II

Phase to 

L1

, Neutral to 

N

1-10V to 

+

and 

, DALI to 

D

D

Notice:

In case the luminaire is equipped with an optional

available surge protector, the function can get tested if the

signal LED is lit green when the supply voltage is turned on.

In case the surge protector is defective, the LED device

gets automatically disconnected from the mains supply. 

If the signal LED is not lit, the luminaire is not functioning.

Hinweis: 

Ist die Leuchte mit einem optional erhältlichen

Überspannungsschutz ausgerüstet, kann die Funktion über-

prüft werden, wenn die Signal-LED bei eingeschalteter

Versorgungsspannung leuchtet. 

Ist der Schutz defekt, wird das LED-Betriebsgerät automa-

tisch vom Netz getrennt. Die Signal-LED leuchtet nicht, die

Leuchte ist ohne Funktion.