Operating Instructions and Parts Manual
4
www.waynepumps.com
S
tep
1:
NOTE: Remove pump from stabilizing mount,
used for shipping and packing.
With motor end of pump facing the “outlet /
inlet” end of the tank, mount pump to tank
with the provided carriage bolts, nuts and
washers as shown (right).
For easy installation, install bolts through
bottom.
The bolts can be entered in any slot
to secure the pump providing they are
positioned diagonally from one another.
NOTE: Pump CAN move slightly, even after
bolts are placed. This provides flexibility when
installing into plumbing.
WASHER
HEX NUT
CARRIAGE
BOLTS
WASHER
HEX
NUT
MOTOR END
TANK OUTLET/INLET
S
tep
2:
Wrap ALL external pipe threads with
plumbers seal tape or other thread
sealant.
NOTE: Start tape about two threads
from bottom of fitting. Wrap tape 2 or
3 turns in the direction of the threads
overlapping each turn. Smooth tape
over threads to make sure there are no
bubbles or loose pieces of tape.
HOSE BARB
PIPE NIPPLE
(THREAD BOTH ENDS)
S
tep
3:
Looking at the pump from the motor
end, screw pipe nipple into the
pump discharge located on the left.
All connections will be fully tightened
in steps 7 & 8.
PIPE NIPPLE
MOTOR END
S
tep
4:
Screw straight hose-barb into pipe tee.
All connections will be fully tightened in
steps 7 & 8.
TEE
FITTING
STRAIGHT
HOSE-BARB