TROUBLESHOOTING CHART

Symptoms

Possible Cause(s)

Suggested Remedies

Pump will not  

start or run 

1.  Power off
2.  Blown fuse or tripped breaker
3.  Faulty pressure switch
4.  Motor overload tripped
5.  Low supply voltage

1.  Turn power on or call power company
2.  Replace fuse or reset circuit breaker
3.  Replace 30/50 pressure switch
4.  Let cool. Overload will automatically reset
5.  Contact an electrician

Motor hums but 

won't run

1.  Line voltage does not match selector switch
2.  Inadequate wiring
3.  Damaged or misalignment causing rotating parts 

to bind

4.  Low supply voltage

1.  Check line voltage and voltage selector switch (see Figure 7 on page 8)
2. Rewire
3.  Replace or take to service shop for repair

4.  Contact an electrician

Overload trips

1.  Low supply voltage
2.  Damaged or misalignment causing rotatin parts 

to bind

3.  High surrounding temperature
4.  Rapid cycling
5.  Inadequate wiring

1.  Contact an electrician
2.  Replace or take to motor replare shop

3.  Provide a shaded, well-ventilated area for pump
4.  See pump starts and stops too often section below
5. Rewire

Pump runs but 

delivers little to no 

water.

NOTE:

 check to 

make sure pump is 

primed before looking 

for other causes. 

Unscrew priming plug 

and see if water is in 

priming hole.

1.  Water level below pump intake
2.  Discharge not vented while priming
3.  Leak in suction piping
4.  Well screen or inlet clogged
5.   Clogged nozzle
6.  Air volume control disphragm ruptured
7.  Foot valve may be clogged or stuck closed
8.  Pump not fully primed

9.  Water level below maximum lift specification
10. Undersized piping
11. Gaseous well
12. Distorted venturi
13. Incorrect jet for application
14. Undersized pump
15. Pump cavitates, sounds like pumping gravel
16. Low supply voltage

1.  Lower suction pipe further into wall
2.  Open faucet to allow air to vent while priming pump
3.  Repair or replace to fix leak
4.  Clean or relace to remove obstruction
5.   Clear obstruction from nozzle
6.  Replace air volume control
7.  Clean or replace as needed
8.  Continue priming, pausing every 5 minutes to cool pump body. Refill pump 

as needed

9.  Select applicable pump and/or jet assembly
10. Replace as needed
11. Install baffle on pump intake to prevent gas from entering system
12. Inspect and replace
13. Purchase a jet matched to your system
14. Increase horsepower of pump
15. Increase suction plumbing diameter or decrease pipe friction
16. Contact an electrician

Pump starts and 

stops too ofen

1.  Water-logged tank (Conventional Tank)
2.  Air volume control tubing kinked or clogged
3.  Air volume control tubing connected to wrong 

opening on pump

4.  Incorrect tank pressure (pre-charged tank)
5.  Ruptured disphragm/bladder (pre-charged tank)
6.  Leak in house piping
7.  Foot valve or check valve stuck open
8.  Motor overload tripping
9.  Improperly adjusted or damage pressure switch

1.  Replace tank or air volume control
2.  Clean or replace as needed
3.  Move to correct pump opening 

4.  Add or release air as needed
5.  Replace tank
6.  Locate and repair leak
7.  Remove and replace
8.   See overload trips section
9.   Replace 30/50 pressure switch

PRÉCAUTIONS ÉLECTRIQUES - Avant tout entretien ou réparation de pompe, TOUJOURS couper le courant au disjoncteur, puis débrancher la pompe. 

S'assurer de ne PAS rester debout dans l'eau, et porter des chaussures à semelles de protection isolées. En cas d'inondation, vérifier auprès de la 

société locale d'électricité ou d'un électricien agréé qualifié pour couper le service électrique avant le retrait de la pompe.

Содержание SWS50-8.5FX

Страница 1: ...ystem Pre Charged Tank www waynepumps com Please read and save these instructions Read carefully before attempting to assemble install operate or maintain the product described Protect yourself and others by observing all safety information Failure to comply with instructions could result in personal injury and or property damage Retain instructions for future reference Operating Instructions and ...

Страница 2: ...ed for pumping potable water in applications where the water is located less than 25 feet vertically from the pump A pressure switch is a standard feature The shallow well pump must be mounted to either a pre charged conventional type or free standing pressure tank Intended for indoor use only Installation of this pump outdoors unprotected from the weather may cause hazardous conditions and will v...

Страница 3: ...0 OFF and is NOT to be changed will void warranty 11 Before installing the pump have the electrical circuit checked by a licensed or certified electrician to make sure the circuit is properly grounded 12 Make sure the line voltage and frequency of electrical current supply agrees with the motor wiring 13 Do NOT attempt repairs to the electric motor All repairs to the motor must be completed by a l...

Страница 4: ...plumbing WASHER HEX NUT CARRIAGE BOLTS WASHER HEX NUT MOTOR END TANK OUTLET INLET Step 2 Wrap ALL external pipe threads with plumbers seal tape or other thread sealant NOTE Start tape about two threads from bottom of fitting Wrap tape 2 or 3 turns in the direction of the threads overlapping each turn Smooth tape over threads to make sure there are no bubbles or loose pieces of tape HOSE BARB PIPE ...

Страница 5: ...tank Hand tighten All connections will be fully tightened in steps 7 8 HOSE BARB ELBOW Step 7 With a pipe wrench tighten pipe tee 1 to 1 1 2 turns aligning hose barb with pump as shown Make sure pipe tee and nipple are tight to prevent leakage Step 8 Tighten hose barb 1 to 1 1 2 turns Make sure the hose barb points toward the top of the tank when tight Do NOT overtighten hose barb elbow Some hose ...

Страница 6: ...he hose clamps over the ends of the hose B Attach the hose with clamps to the hose barb using a twisting motion on the hose while pushing it over the hose barb A B Step 10 Tighten the hose clamps on the hose over the hose barb fittings If a leak is detected after system is installed tighten hose clamps just enough to stop the leak Do NOT overtighten hose clamps Do NOT exceed 40 in lbs of torque B ...

Страница 7: ...well should be pumped clear of sand before installing the pump Sand will damage the pumping parts and seal The draw down level of the well should not exceed the maximum rated depth for the pump The capacity of the pump will be reduced and a loss of prime may occur PIPING Inlet piping may be copper steel or rigid PVC plastic Flexible pipe is prohibited on suction pipe inlet pipe MISE EN GARDE Un tu...

Страница 8: ...O PUMP PACKER TYPE FOOT VALVE Figure 2 Figure 2 Illustration B Illustration B Figure 2 Illustration C DRIVE POINT TO PUMP IN LINE CHECK VALVE DUG WELL CISTERN LAKE AND SPRING INSTALLATION FIGURE 12 ON PAGE 14 1 Install a foot valve on inlet pipe and lower into water The foot valve MUST be at least 18 from the bottom of the well or sand or sediment WILL be drawn into the system MISE EN GARDE Le cla...

Страница 9: ...re used run a wire directly to the metal well casing or use a ground electrode furnished by the power company There is only one proper ground terminal on the unit The terminal s is located under the pressure switch cover is painted green and is identified as GRD The ground connection must be made at this terminal Figure 5 The ground conductor must not be smaller than the circuit conductors supplyi...

Страница 10: ...her de la source d alimentation puis dissiper toute la pression du système avant d essayer d installer de réparer de déplacer ou de procéder à l entretien Verrouiller le sectionneur de courant en position ouverte OFF Étiqueter le sectionneur de courant pour éviter toute mise sous tension imprévue Protect the pump from freezing during winter conditions MISE EN GARDE Protéger la pompe du gel pendant...

Страница 11: ...raining and priming 3 Place rotating shaft seal member in position on impeller and press into place Take care not to press against polished seal surface 4 Position impeller on shaft and tighten securely Figure 11 5 Secure diffuser to seal plate using the two cap screws Be sure the arrow on the front of the diffuser is pointing up and the screws are orientated on a horizontal line as described in S...

Страница 12: ...arts in reverse order 14 Wipe down the seal plate to remove any debris or loose rust 15 Push the ceramic seat of the shaft seal into the seal plate using the cardboard ring provided to keep the ceramic face clean You can use a little water or dish soap to lubricate the seal pocket to make assembly easier 16 Slide the square cut gasket over the flange on the seal plate make sure not to let the gask...

Страница 13: ... control disphragm ruptured 7 Foot valve may be clogged or stuck closed 8 Pump not fully primed 9 Water level below maximum lift specification 10 Undersized piping 11 Gaseous well 12 Distorted venturi 13 Incorrect jet for application 14 Undersized pump 15 Pump cavitates sounds like pumping gravel 16 Low supply voltage 1 Lower suction pipe further into wall 2 Open faucet to allow air to vent while ...

Страница 14: ... lined with brick stone or concrete to prevent cave in D DRIVEN WELL Pipe with a pointed screen is driven into the ground below the water table The depth is usually less than 50 feet Available diameters are 1 through 2 E DRILLED WELL A hole bored into the earth with machinery and lined with pipe Depths range from a few feet to over 1000 feet Common well diameters are 2 3 4 and 6 for domestic water...

Страница 15: ...SSED OR IMPLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE AND ANY RIGHTS OR REMEDIES AGAINST ANY PERSON OR ENTITY UNDER THE UNIFORM COMMERCIAL CODE OR OTHERWISE WITH RESPECT TO THE SALE OF THE PRODUCT THE REMEDIES AND OBLIGATIONS STATED IN THIS WARRANTY ARE THE SOLE AND EXCLUSIVE REMEDIES OF AND OBLIGATIONS TO THE OWNER FOR ANY AND ALL MATTERS ARISING ...