Wayne PC4 Скачать руководство пользователя страница 2

www.waynepumps.com

Operating Instructions and Parts Manual

2

GENERAL SAFETY INFORMATION (CONTINUED)

 

Pump motor is equipped with an automatic 

  resetting thermal protector and MAY restart 

unexpectedly. Protector tripping is an indication of motor overheating 

because of operating pump at low heads (low discharge restriction), 

excessively high or low voltage, inadequate wiring, excessive surrounding 

air temperature, inadequate ventilation, and/or defective motor or pump.

5.  Provide a means of pressure relief in the case of an obstructed 

discharge line.

6.  Protect electrical cord from sharp objects, hot surfaces, oil and 

chemicals. Avoid kinking the cord and replace damaged cords 
immediately.

INSTALLATION

   

ALWAYS disconnect power source before attempting to 

operate, service, or maintain the pump. NEVER handle a pump 

with wet hands or when standing on wet or damp surface or 

in water. Fatal electrical shock WILL occur.

1.  A ground fault circuit interrupter (GFCI) is required.

   

Risk of electrical shock! This pump is supplied with a 

grounding conductor and grounding type attachment plug.  

A grounded receptacle in conformance with current NEC and 

local codes must be used (See Figure 1).

2.   This pump operates on 115V, 60 Hz AC, single phase or 115V 

DC.

3.   Use an extension cord only if necessary. Follow the Extension 

Cord Length Table for proper gage of 3-wire, grounding type 
extension cord.

Extension Cord Length Table

Wire Size

#18

#16

#14

#12

Length

25 ft

50 ft

100 ft

150 ft

 

Risk of fatal electrical shock. NEVER cut off the round 

grounding prong. Cutting the cord or plug WILL void the 

warranty and make the pump inoperable.

TEST

RESET

GROUNDING BLADE

GFCI RECEPTACLE

Figure 1

4.   Figure 2 shows a typical installation. Threaded adapters are 

furnished for attaching garden hose where conditions permit its 
use. In no case should the pump be more than 15 feet above 
or away from water source. Install a foot valve when suction lift 
is over 10 feet or when suction line is over 10 feet long.

5.  The inlet line may be galvanized pipe, plastic pipe, or reinforced 

hose. Small leaks in suction line 

greatly

 reduce efficiency of 

pump and may prevent priming. 

 

Ordinary garden hose WILL collapse under 

  suction pressure and SHOULD NOT be used for 

the inlet line, except in pressure boosting applications.

6.  Use a strainer when pumping from a creek, pond, or source 

where foreign objects may be sucked into the pump. The 
strainer should prevent solids from entering the inlet line.

7.  A regular garden hose may be used as a discharge line.

OPERATION

 

Pump must be filled with water before 

  operation. Running the pump dry WILL cause 

damage to the shaft seal.

1.   This unit is 

not

 waterproof or weatherproof and is 

not

 

intended to be used in showers, saunas, or other potentially 
wet locations. The motor is designed to be used in a clean, 
dry location with access to adequate cooling air. Ambient 
temperatures around the motor should not exceed 104˚F (40˚C).

2.   Remove priming plug and fill with water. Replace plug (plumbers 

seal tape should be used on priming plug to prevent air leaks).

3.   Plug power cord into GFCI protected electrical outlet. The 

pump will prime in a few minutes depending on suction line 
length. Use of foot valve on suction line is recommended.

4.   In the case of pressure boosting, turn water on before starting 

pump. This force primes the pump. Then, plug power cord into 
GFCI protected electrical outlet.

5.  Unplug cord to turn unit off.

OUTLET

PRIME PLUG

HOSE 
ADAPTERS

INLET

Figure 2

Содержание PC4

Страница 1: ...for safekeeping 2016 WAYNE Scott Fetzer Company DESCRIPTION This self priming portable utility pump is designed to be used as a transfer pump for such applications as emptying water heaters livestock...

Страница 2: ...NG BLADE GFCI RECEPTACLE Figure 1 4 Figure 2 shows a typical installation Threaded adapters are furnished for attaching garden hose where conditions permit its use In no case should the pump be more t...

Страница 3: ...g with the flats on the brush hlder REF fig3 5 Replace brush caps For other problems consult troubleshooting chart NOTES __________________________________________________________ ____________________...

Страница 4: ...on the seal seats against the back head and making sure the black carbon side of the seal is facing away from the back head towards the impeller 10 Push the ceramic seal into the impeller pocket makin...

Страница 5: ...oo high 4 Lower pump 5 Hose kinked or looped 5 Straighten hose 6 Fittings not tight 6 Tighten fittings 7 Suction hose out of water 7 Submerge suction hose end 8 Clogged inlet 8 Clean inlet Flow rate i...

Страница 6: ...101 Production Drive Harrison OH 45030 U S A 6 For Replacement Parts or Technical Assistance call 1 800 237 0987 Please provide following information Model number Serial number if any Part description...

Страница 7: ...states do not allow limitations on how long an implied warranty lasts or do not allow the exclusions or limitations of incidental or consequential damages so the above limitations might not apply to y...

Страница 8: ...www waynepumps com Operating Instructions and Parts Manual 8 NOTES...

Страница 9: ...toda la presi n del sistema antes de darle servicio a cualquier componente 3 Drene todos los l quidos del sistema antes de darle servicio DESCRIPCI N Las bombas port tiles de servicio con sistema de c...

Страница 10: ...EGURIDAD CONTINUACION Asegure la l nea de descarga antes de dar arranque a la bomba Si no la asegura ES POSIBLE que se sacuda bruscamente y PODR AN causarse lesiones personales y o da os a la propieda...

Страница 11: ...tarle las escobillas y quitarle los residuos de carb n Las escobillas no est n cubiertas en la garant a Para ordenar escobillas de repuesto comun quese con el distribuidor de bombas WAYNE m s cercano...

Страница 12: ...ezal trasero y asegur ndose de que el lado de carb n negro del sello est orientado lejos del cabezal trasero y hacia el impulsor 10 Empuje el sello de cer mica hacia dentro de la cavidad del impulsor...

Страница 13: ...guera est enrollada 5 Enderece la manguera 6 Las conexiones est n flojas 6 Apriete las conexiones 7 La manguera de succi n no tiene agua 7 Sumerja el extremo de la manguera de succi n 8 El orificio de...

Страница 14: ...dor M s Cercano a Su Domicilio Sirvase darnos la siguiente informaci n Dirija toda la correspondencia a N mero del modelo Wayne Water Systems C digo impreso 101 Production Drive Descripci n y n mero d...

Страница 15: ...www waynepumps com PC4 Sp 15 NOTES...

Страница 16: ...A O INDIRECTA COMO CONSECUENCIA DE DA OS SON EXCLUIDAS Algunos estados no permiten l mites en la duraci n de las garant as o no permiten que se limiten o excluyan casos por da os por accidentes o cons...