Wayne PC4 Скачать руководство пользователя страница 1

GENERAL SAFETY INFORMATION

CALIFORNIA PROPOSITION 65

 

This product or its power cord contains 

  chemicals, including lead, known to the State of 

California to cause cancer and birth defects or other reproductive harm. 

Wear gloves when handling this product, and wash hands after handling. 

GENERAL SAFETY

 

Do not submerge motor or allow motor to be 

  exposed to water. Personal injury and/or death 

WILL result.

   

Do NOT use to pump flammable or explosive fluids such as 

gasoline, fuel oil, kerosene, etc. Do NOT use in a flammable 

and/or explosive atmosphere. Pump SHOULD only be used to 

pump clear water. Personal injury and/or death WILL result.

 

Risk of electrical shock. ALL wiring must be 

  performed by a qualified electrician.

   

Do NOT walk on wet areas until ALL power is turned off. 

Failure to follow this warning WILL result in fatal electrical 

shock.

1.  Read all instructions before operation.
2.  Disconnect power and release all pressure within 

the system before servicing any component.

3.   Drain all liquids from system before servicing.

 

Secure the discharge line before starting the 

  pump. An unsecured discharge line MAY whip. 

Personal injury and/or property damage COULD result.

4.  Periodically inspect pump and system components, checking 

for weak and/or worn hoses. Insure all connections are secure.

  

PC4

Self-Priming  
Portable Utility Pump

OPERATING INSTRUCTIONS & PARTS MANUAL

READ, UNDERSTAND AND FOLLOW ALL INSTRUCTIONS IN THIS MANUAL - DO NOT DISCARD.  

Failure to follow these instructions could result in property damage, serious injury or death.

For parts, product & service information visit

 www.waynepumps.com

REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.

© 2016, WAYNE/Scott Fetzer Company.

 

DESCRIPTION

This self-priming portable utility pump is designed to be used as 
a transfer pump for such applications as emptying water heaters, 
livestock tanks, etc. Pump can also be used for an intermittent 
pressure boost for applications such as washing cars, cleaning 
driveways, etc. The motor is air cooled; it is 

not

 designed to operate 

under water. 

NOTE:

 This pump is not intended for permanent installation or long, 

extended periods of continuous operation.

UNPACKING

After unpacking the utility pump, carefully inspect for any damage 
that may have occurred during transit. Check for loose, missing or 
damaged parts. If you need assistance, call our Customer Service 
Department at 1-800-237-0987.

SAFETY GUIDELINES

To help recognize this information, observe the following signal 
words/hazard classifications.

 

Danger indicates an imminently hazardous 

  situation which, if not avoided, WILL result in 

death or serious injury.

 

Warning indicates a potentially hazardous 

  situation which, if not avoided, COULD result in 

death or serious injury.

 

Caution indicates a potentially hazardous 

  situation which, if not avoided, MAY result in 

minor or moderate injury.

 

Notice indicates important information, that if 

  not followed, may cause damage to equipment.

 

This is the safety alert symbol. It is used to alert you to  potential bodily   

 

injury hazards. Obey all safety messages that follow this symbol to avoid  

 

possible harm.

NOTE: 

Information that requires special attention.

Specifications

Motor

Single Phase - 115V, 60 Hz, 8,000 RPM

Horsepower

1/2 HP

Motor

Series Wound (brush type) AC/DC Operation

Inlet/Outlet Openings

3/4 inch NPT

Impeller

Thermoplastic

Pump Housing

Cast iron

Motor Housing

Cast iron

Motor Shaft

Cold rolled steel

Shaft and Volute 
Seal

Buna-N

Motor Bearings

Permanently lubricated 
Rolling element bearings

Maximum Fluid 
Temperature

120°F

3213 

07

 -001 6/16

Содержание PC4

Страница 1: ...for safekeeping 2016 WAYNE Scott Fetzer Company DESCRIPTION This self priming portable utility pump is designed to be used as a transfer pump for such applications as emptying water heaters livestock...

Страница 2: ...NG BLADE GFCI RECEPTACLE Figure 1 4 Figure 2 shows a typical installation Threaded adapters are furnished for attaching garden hose where conditions permit its use In no case should the pump be more t...

Страница 3: ...g with the flats on the brush hlder REF fig3 5 Replace brush caps For other problems consult troubleshooting chart NOTES __________________________________________________________ ____________________...

Страница 4: ...on the seal seats against the back head and making sure the black carbon side of the seal is facing away from the back head towards the impeller 10 Push the ceramic seal into the impeller pocket makin...

Страница 5: ...oo high 4 Lower pump 5 Hose kinked or looped 5 Straighten hose 6 Fittings not tight 6 Tighten fittings 7 Suction hose out of water 7 Submerge suction hose end 8 Clogged inlet 8 Clean inlet Flow rate i...

Страница 6: ...101 Production Drive Harrison OH 45030 U S A 6 For Replacement Parts or Technical Assistance call 1 800 237 0987 Please provide following information Model number Serial number if any Part description...

Страница 7: ...states do not allow limitations on how long an implied warranty lasts or do not allow the exclusions or limitations of incidental or consequential damages so the above limitations might not apply to y...

Страница 8: ...www waynepumps com Operating Instructions and Parts Manual 8 NOTES...

Страница 9: ...toda la presi n del sistema antes de darle servicio a cualquier componente 3 Drene todos los l quidos del sistema antes de darle servicio DESCRIPCI N Las bombas port tiles de servicio con sistema de c...

Страница 10: ...EGURIDAD CONTINUACION Asegure la l nea de descarga antes de dar arranque a la bomba Si no la asegura ES POSIBLE que se sacuda bruscamente y PODR AN causarse lesiones personales y o da os a la propieda...

Страница 11: ...tarle las escobillas y quitarle los residuos de carb n Las escobillas no est n cubiertas en la garant a Para ordenar escobillas de repuesto comun quese con el distribuidor de bombas WAYNE m s cercano...

Страница 12: ...ezal trasero y asegur ndose de que el lado de carb n negro del sello est orientado lejos del cabezal trasero y hacia el impulsor 10 Empuje el sello de cer mica hacia dentro de la cavidad del impulsor...

Страница 13: ...guera est enrollada 5 Enderece la manguera 6 Las conexiones est n flojas 6 Apriete las conexiones 7 La manguera de succi n no tiene agua 7 Sumerja el extremo de la manguera de succi n 8 El orificio de...

Страница 14: ...dor M s Cercano a Su Domicilio Sirvase darnos la siguiente informaci n Dirija toda la correspondencia a N mero del modelo Wayne Water Systems C digo impreso 101 Production Drive Descripci n y n mero d...

Страница 15: ...www waynepumps com PC4 Sp 15 NOTES...

Страница 16: ...A O INDIRECTA COMO CONSECUENCIA DE DA OS SON EXCLUIDAS Algunos estados no permiten l mites en la duraci n de las garant as o no permiten que se limiten o excluyan casos por da os por accidentes o cons...

Отзывы: