background image

4.   Fill sump with water. The pump will

start automatically when the water
has filled the sump to a depth of
approximately 13“. The pump will
stop when the water depth is
approximately 7”. The pump will
recycle thereafter as required.

5.   Do not operate the pump unless it is

submerged in water. Dry running
causes pump failure.

6.   The motor is equipped with an

automatic reset thermal protector. 

7.   While the pump is draining the pit,

verify that the discharge piping is
carrying the water to a point several
feet away from the foundation.

8.  If pump discharge line is exposed to

freezing temperature, the exposed
line must be pitched to drain.
Trapped water will freeze and
damage the pump.

Maintenance

Always disconnect  the
electrical supply before
attempting to install,
service, relocate or
perform any maintenance. If the power
source is out of sight, lock and tag in

supplied with a grounding conductor
and grounding type attachment plug.
Use a grounded receptacle to reduce
the risk of fatal electrical shock.

Never cut off the round grounding
prong. Cutting the cord or plug will
void the warranty and make the pump
inoperable.

2.   This pump is only for use on 120

Volt (single-phase), 60 hz, 15 amp
service and is equipped with a 3-
conductor cord and 3-prong,
grounding type plug. Insert the
float switch cord plug directly into
a 120 volt outlet.

3.   Insert the pump power cord plug

directly into the back of the float
switch cord plug (See Fig. 2).

2

Operating Instructions And Parts Manual

Troubleshooting Chart

Symptom

Possible Cause(s)

Corrective Action

Pump will not start
or run

Pump starts and
stops too often

Pump will not shut
off or thermal
protector turns off

Pump operates but
delivers little or no
water

1. Blown fuse
2. Low line voltage
3. Defective motor
4. Defective float switch
5. Impeller
6. Float obstructed

1. Backflow of water from

piping

2. Faulty float switch

1. Defective float switch
2. Obstacle in piping
3. Float obstructed

1. Low line voltage
2. Plugged impeller

1. If blown, replace with proper sized fuse or reset breaker.
2. If voltage is under 108 volts, check wiring size.
3. Replace pump
4. Replace float switch
5. If impeller will not turn, remove housing and remove blockage
6. Make sure float move freely up and down

1. Install or replace check valve (Wayne No. 66005-WYN)

2. Replace float switch

1. Replace float switch
2. Remove pump and clean pump and piping
3. Make sure float moves freely up and down

1. If voltage is under 108 volts, check wiring size.
2. Clean out impeller

the open (off) position to prevent
unexpected power application. Failure
to do so could result in fatal electrical
shock. Only qualified electricians
should repair this unit. Improper repair
could result in fatal electrical shock.

1.   Let the pump cool for a minimum

of two hours before servicing
because the pump contains hot oil
under pressure and the motor is
hot.

2.   Disassembly of the motor prior to

expiration of warranty will void the
warranty. If repairs are required,
see troubleshooting chart.

4.   Inlet should be kept clean and free

of all foreign objects and inspect
annually. A clogged inlet will
damage pump.

5.   Pump should be checked monthly

for proper operation. 

This pump contains 
dielectric oil for

cooling. This oil can be harmful to the
environment. Check the state
environmental laws before disposing
this oil.

www.waynewatersystems.com

Figure 2

Содержание 351002-001

Страница 1: ...800 237 0987 for backup model number Installation 1 Install pump in a sump pit with minimum size as shown below Construct sump pit of tile concrete steel or plastic 2 The unit should be located and r...

Страница 2: ...run Pump starts and stops too often Pump will not shut off or thermal protector turns off Pump operates but delivers little or no water 1 Blown fuse 2 Low line voltage 3 Defective motor 4 Defective fl...

Страница 3: ...s 101 Production Drive Harrison OH 45030 Specifications Power supply requirements 120V 60 hz Motor Single phase oil filled Horsepower 1 3 HP CDT33 SPT33 SSPT33 1 2 HP CDT50 SPT50 SSPT50 Liquid tempera...

Страница 4: ...INDIRECT OR CONSEQUENTIAL DAMAGES OR EXPENSES WHATSOEVER IS EXCLUDED Some states do not allow limitations on how long an implied warranty lasts or do not allow the exclusions or limitations of incide...

Страница 5: ...ulter en secousse lectrique mortelle Un syst me de sauvegarde doit tre utilis Composer le 1 800 237 0987 pour le num ro de mod le du syst me de sauvegarde Installation 1 Installer la pompe dans une fo...

Страница 6: ...rop souvant La pompe ne s arr te pas ou le protecteur thermique s arr te La pompe fonctionne mais refoule peu ou pas d eau 1 Fusible saut 2 Tension de ligne basse 3 Moteur d fectueux 4 Interrupteur fl...

Страница 7: ...Production Drive Harrison OH 45030 Sp cifications Exigences d alimentation 120V 60 Hz Moteur Monophas rempli d huile Puissance 1 3 HP CDT33 SPT33 SSPT33 1 2 HP CDT50 SPT50 SSPT50 Gamme de temp rature...

Страница 8: ...QUEL ET TOUT DOMMAGES INDIRECTS OU D PENSES QUOI QUE SE SOIT EST EXCLUS Certaines Provinces n autorisent pas de limitations de dur e pour les garanties implicites ni l exclusion ni la limitation des d...

Отзывы: