background image

Important Safety Instructions

DEFINITION OF KEY WORDS USED IN THIS MANUAL:

WARNING 

INDICATES A POTENTIALLY HAZARDOUS SITUATION WHICH; IF NOT 

AVOIDED, COULD RESULT IN SEVERE OR FATAL INJURY.

CAUTION 

PROPERTY DAMAGE OR INJURY CAN RESULT FROM FAILURE TO FOLLOW 

INSTRUCTIONS.

IMPORTANT: 

REQUIRED STEP FOR SAFE AND PROPER DOOR OPERATION.

NOTE:

 Information assuring proper installation of the door.

READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING INSTALLATION. IF 

IN QUESTION ABOUT ANY OF THE PROCEDURES, DO NOT PERFORM THE WORK. 

INSTEAD, HAVE A TRAINED DOOR SYSTEMS TECHNICIAN DO THE INSTALLATION OR 

REPAIRS.
1.

 

READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS.

2.

 

Wear protective gloves during installation to avoid possible cuts from sharp metal 

edges.

3.

 

It is always recommended to wear eye protection when using tools, otherwise eye 

injury could result.

4.

 

Avoid installing your new door on windy days. Door could fall during the installation 

causing severe or fatal injury.

5.

 

Doors 12’-0” wide and over should be installed by two persons, to avoid possible 

injury.

6.

 

Operate door only when it is properly adjusted and free from obstructions.

7.

 

If a door becomes hard to operate, inoperative or is damaged, immediately have 

necessary adjustments and/ or repairs made by a trained door system technician using 

proper tools and instructions.

8.

 

DO NOT stand or walk under a moving door, or permit anybody to stand or walk under 

an electrically operated door.

9.

 

DO NOT place fingers or hands into open section joints when closing a door. Use lift 

handles/ gripping points when operating door manually.

10.

  DO NOT permit children to operate garage door or door controls. Severe or fatal injury 

could result should the child become entrapped between the door and the floor.

11.

  Due to constant extreme spring tension, do not attempt any adjustment, repair or 

alteration to any part of the door, especially to springs, spring brackets, bottom corner 

brackets, fasteners, counterbalance lift cables or supports. To avoid possible severe or 

fatal injury, have any such work performed by a trained door systems technician using 

proper tools and instructions.

12.

  On electrically operated doors, pull down ropes must be removed and locks must be 

removed or made inoperative in the open (unlocked) position.

13.

  Top section of door may need to be reinforced when attaching an electric opener. 

Check door and/ or opener manufacturer’s instructions.

14.

  Visually inspect door and hardware monthly for worn and or broken parts. Check to 

ensure door operates freely.

15.

  Test electric opener’s safety features monthly, following opener manufacturer’s instruc-

tions.

16.

  NEVER hang tools, bicycles, hoses, clothing or anything else from horizontal tracks. 

Track systems are not intended or designed to support extra weight.

17.

  This door may not meet the building code wind load requirements in your area. For 

your safety, you will need to check with your local building official for wind load code 

requirements and building permit information.

18.

  For windloaded doors, the wind performance is achieved via the entire door system 

and component substitution is not authorized without express permission by Wayne 

Dalton.

NOTE:

 It is recommended that 5/16” lag screws are pilot drilled using a 3/16” drill bit, prior 

to fastening.

CAUTION 

IF ANY PART OF THE DOOR IS TO BE INSTALLED ONTO PRESERVATIVE-

TREATED WOOD, PTFE-COATED OR STAINLESS STEEL FASTENERS MUST BE 

OBTAINED AND USED. REPLACEMENT FASTENERS MUST BE OF AT LEAST 

EQUAL STRENGTH AND SIZE AS ORIGINAL FASTENERS. IF THE ORIGINAL 

FASTENER WAS RED-HEAD, THE REPLACEMENT FASTENER MUST BE RED-

HEAD ALSO. CONTACT WAYNE DALTON FOR FASTENER STRENGTH VALUES IF 

NEEDED.

WARNING 

IMPACT GUNS ARE NOT RECOMMENDED. WHEN INSTALLING 5/16” LAG 

SCREWS USING AN ELECTRIC DRILL/ DRIVER, THE DRILL/ DRIVERS 

CLUTCH MUST BE SET TO DELIVER NO MORE THAN 200 IN-LBS OF 

TORQUE. FASTENER FAILURE COULD OCCUR AT HIGHER SETTINGS.

IMPORTANT: 

RIGHT AND LEFT HAND IS DETERMINED INSIDE THE BUILDING LOOKING OUT.

Potential Hazard

Effect

Prevention

 

Moving door

   WARNING

Could result in Death or Serious 

Injury

Keep people clear of opening 

while Door is moving.

Do 

NOT

 allow children to play 

with the Door Opener.

Do 

NOT

 operate a Door that 

jams or one that has a broken 

spring.

High tension spring

   WARNING

Could result in Death or Serious 

Injury

Do 

NOT

 try to remove, install, 

repair or adjust springs or 

anything to which door spring 

parts are fastened, such as, 

wood blocks, steel brackets, 

cables or other like items.

Installations, repairs and 

adjustments must be done by 
a trained door system techni-

cian using proper tools and 

instructions.

Removing an Existing Door 

and Preparing the Opening

IMPORTANT: 

COUNTERBALANCE SPRING TENSION MUST ALWAYS BE RELEASED BEFORE 

ANY ATTEMPT IS MADE TO START REMOVING AN EXISTING DOOR.

WARNING 

A POWERFUL SPRING RELEASING ITS ENERGY SUDDENLY CAN CAUSE 

SEVERE OR FATAL INJURY. TO AVOID INJURY, HAVE A TRAINED DOOR 

SYSTEMS TECHNICIAN, USING PROPER TOOLS AND INSTRUCTIONS, 

RELEASE THE SPRING TENSION.

To avoid possible injury and to insure proper installation, it's highly recommended that you 

read and fully understand the complete instructions on removing an Existing Door & Prepar-

ing the Opening. These are available for download at 

www.Wayne-Dalton.com

 or at your 

local Wayne Dalton Sales Center.

WEATHERSTRIPS (MAY NOT BE INCLUDED):

Depending on the size of your door, you may have to cut or trim the weatherstrips (if neces-

sary) to properly fit into the header and jambs.

NOTE:

 If nailing product at 40°F or below, pre-drilling is required.

NOTE:

 Do not permanently attach weatherstrips to the header and jambs at this time.

For the header, align the weatherstrip 1/8” to 1/4” inside the header edge, and temporarily 

secure it to the header with equally spaced nails. Starting at either side of the jamb, fit the 

weatherstrip up tight against the temporarily attached weatherstrip in the header and 1/8” 

to 1/4” inside the jamb edge. Temporarily secure the weatherstrip with equally spaced nails. 

Repeat for other side. This will keep the bottom section from falling out of the opening during 

installation. Equally space nails approximately 12” to 18” apart.

2

Pre-Installation

Содержание Torsion 7100 Series

Страница 1: ...arage Door 12 Operation And Maintenance 12 Warranty 13 Wayne Dalton a division of Overhead Door Corporation Model 7100 Series T o r s i o n Quick Start Guide Residential and Light Commercial Standard...

Страница 2: ...t information 18 For windloaded doors the wind performance is achieved via the entire door system and component substitution is not authorized without express permission by Wayne Dalton NOTE It is rec...

Страница 3: ...d and Right Hand Cable Drums J5 Center Bracket As Required J6 Center Bearing As Required J7 Torsion Shaft Torsion Keyed Shaft As Required J8 Torsion Keyed Shafts As Required J9 Keys As Required J10 Ce...

Страница 4: ...ation section of this manual or refer to Breakdown of Parts With the bottom section facing down from the previous step uncoil the counterbalance lift cables NOTE Refer to Package Contents Breakdown of...

Страница 5: ...CK ROLLER IF INCLUDED GOES INTO TUBE FURTHEST AWAY FROM SECTION Attaching Hinges and Strut To Intermediate Section s 6 NOTE Refer to door section identification located in the pre installation section...

Страница 6: ...SECTION WAS SHIMMED TO LEVEL IT THE VERTICAL TRACK ON THE SHIMMED SIDE MUST BE RAISED THE HEIGHT OF THE SHIM NOTE Make sure the counterbalance lift cable is located between the track rollers and the d...

Страница 7: ...INED FROM INSIDE THE BUILDING LOOKING OUT NOTE End bearing brackets are right and left hand DEPENDING ON WHICH END BEARING BRACKET YOU HAVE Either attach the left hand end bearing bracket to the left...

Страница 8: ...and left hand by the set screw color IF YOU DON T HAVE A COUPLER ASSEMBLY Facing the inside of the door lay the torsion shaft torsion keyed shaft on the floor Lay the torsion spring with the black win...

Страница 9: ...kets If your spring diameter is either 2 or 2 5 8 then two springs will share the same center bracket unless a coupler assembly is provided IF YOU DON T HAVE A COUPLER ASSEMBLY Slide center bracket be...

Страница 10: ...ical tracks just above the third track roller This is to prevent the garage door from rising while winding springs NOTE Check the following before attempting to wind torsion spring s a Counterbalance...

Страница 11: ...LOCKING PLIERS FROM VERTICAL TRACKS Raise the door until the top section and half of the next section are in the horizontal track radius Do not raise door any further since rear of horizontal tracks a...

Страница 12: ...ter pins clevis pins are under HIGH SPRING TENSION Adjustments and repairs must only be made by a trained door systems technician using proper tools and instructions DO NOT REMOVE COVER OR PAINT OVER...

Страница 13: ...s door located as spelled out in the installation instructions even if the door is motor operated Failure to install and use these lift handles gripping points on this door can result in serious injur...

Страница 14: ...after discovery within the applicable warranty period and in writing to the Seller whose name and address appear below The purchaser must allow Seller a reasonable opportunity to inspect any Product c...

Страница 15: ......

Страница 16: ...rvice representative They will be happy to handle any questions that you may have Thank you for your purchase PLEASE DO NOT RETURN THIS PRODUCT TO THE STORE After installation is complete leave this I...

Отзывы: