background image

Water Tank Drainage

Before starting the machine, please ensure that the air outlet has been opened, 
otherwise the machine will overheat.

Do not stop by directly unplug the power line.

When the water tank is full, the water full indicator will light up, the dehumidifier 
will automatically shut down until the tank has been emptied and placed back to 
the unit.

Hold the water tank with 
both your hands, and 
pull out the tank gently.

Put the water tank back 
in place and the full tank 
indicator will go out.

Ways to Empty the Water Tank

5. Empty The Water Tank

Do not remove the float from the water tank. If the float in the water tank is 
removed, the sensor may not be able to determine the water level stored in 
the tank properly that may lead to water overflow leak from the water tank. 

If the water tank is dirty, just use cold water or warm water to clean it. Do not 
use detergent, steel wool, chemically treated dust cloth, gasoline,benzene, 
thinner or other solvents. Otherwise, it may damage the water tank and cause 
it to leak. 

When placing back the water tank, use your hands to press the tank back in 
its place. If the water tank is not placed properly, sensors or protections from 
water overflow may not operate as expected. 

Note:

OPERATION INSTRUCTIONS

Содержание PD100A

Страница 1: ...Home Dehumidifier Please read the manual carefully before using the unit PD100A USER MANUAL ...

Страница 2: ... use of the dehumidifier Our dehumidifiers are widely used in family bedrooms bathrooms basements offices and storage rooms etc The dehumidifiers from provide quick and efficient operation to Waykar reduce room s humidity and bring you a healthy and comfortable life If there is any problem of the product please contact Waykar Customer Service at with your Purchase Order ID to help you support wayk...

Страница 3: ...ernal damage it is very important to keep the unit like this one upright throughout its journey Please leave it standing as the picture shown below and outside the box for before plugging it in 24 HOURS BEFORE FIRST USE ...

Страница 4: ...functions provided in this manual may not be the same as the actual product Please always refer to the actual product The model of the machine on the manual is for reference only Please operate the machine based on the actual product The right to interpret the relevant terms belongs to the company ...

Страница 5: ...n must be equipped with an all pole disconnect device air switch with at least 0 118 inch distance of electric shock This appliance can not be used by children aged under 8 years old and persons withreduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instructions concerning use of the appliance in a safe way and understand ...

Страница 6: ...Side of the Machine Back of the Machine Product components Description 1 Control Panel 2 Outlet 3 Front Cover 4 Handle 5 Inlet 6 Continuous Drainage Outlet 7 Water Tank ...

Страница 7: ...d Button Digital Display Setting Button Power Button Button Description Power Button Switch control of the machine Speed Button Used for high wind and low wind switching Setting Button Used for humidity setting Timing button Used for timing checking and setting CONTROL PANEL ...

Страница 8: ...ction is designed for you to set a time to turn off or turn on the machine automatically by the timer 1 Press the Timing button to select the timer by 1 hour increment You can set the timer up to 24 hours It will start to do the countdown when you start the timer 2 If the time is set to 00 this is called the invalid time If you set the timer successfully the Timing light will be on The LED screen ...

Страница 9: ...ically determine whether there is a presence of frost If any frost exists it will defrost automatically Defrost Action The fan runs at high wind speed when the compressor stops and the LED screen displays the defrosting symbol When defrosting status the defrosting light will flash Action Description Power on Compressor starts after the fan work for a few seconds Power off Compressor shuts down at ...

Страница 10: ...ity to 30 RH the dehumidifier can still continue to work and can be used normally Repair and replace the humidity sensor 1 Water on the surface of the humidity sensor 2 Humidity sensor failure The dehumidifier is not affected and can continue to work and can be used normally Repair and replace the humidity sensor Please let the dehumidifier keep working for a period of time after the water on the ...

Страница 11: ...er Tank 5 Empty The Water Tank Do not remove the float from the water tank If the float in the water tank is removed the sensor may not be able to determine the water level stored in the tank properly that may lead to water overflow leak from the water tank If the water tank is dirty just use cold water or warm water to clean it Do not use detergent steel wool chemically treated dust cloth gasolin...

Страница 12: ...continuous drainage port from the water tank and then insert the hose to realize continuous drainage the outlet of water hose should be 10cm lower than the continuous drainage port so as to ensure smooth drainage 6 Continuous Drainage Continuous Drainage Port Water Tank OPERATION INSTRUCTIONS ...

Страница 13: ... If the filter is very dirty clean it with warm water and mild detergent and dry it completely 3 Slowly insert the filter back into the machine body When you want to store the dehumidifier because you don t use it for a long time Please pay attention to the following steps 1 Empty the water in the water tank 2 Roll up the power cord and tie it up 3 Clean the filter 4 Place the machine in a cool an...

Страница 14: ...ly defrost which is a normal phenomenon It will restart dehumification again until the defrosting process finished It is normal the compressor ceases while defrosting process Wait until the process finished it will restart dehumidification again Is the room humidity lower or reaching the preset humidity level When the room humidity has reached the preset level the dehumidifier will enter Standby M...

Страница 15: ...ture Please wait until the temperature rises to above 5 or higher Clean up the dirt or lint on the air outlet and intake Continuous Mode Do Not set the humidity too low Typically 40 50 are good for use Please check whether the packing bag of the filter had been removed and the filter has been installed correctly The to to levelly ...

Страница 16: ...stuck Re install the water tank properly Move the float and let it swing freely If the dehumidifier is still not working properly as expected and the troubleshooting steps or solutions above may not resolve the issue please unplug the power and shut down the dehumidifier then contact Waykar Customer Service at support waykar com ...

Страница 17: ...t textile to wipe gently do not shoot the water directly Please clean the filter every two weeks do not use hot water above 104 F alcohol gasoline or toluene When continuous drainage the drain hose must be placed horizontally without unevenness and winding After cleaning the filter please do not dry it under direct sunlight in case deformation ...

Страница 18: ...icals including Styrene and its compounds which is known to the State of California to cause cancer and birth defects or other reproductive harm For more information please visit www P65Warning ca gov MOISTURE REMOVAL CAPACITY 659F 60 RH ...

Страница 19: ... apply if damage is caused by other factors including but without limitation of Please fill out all required fields and inlcude your Order ID Date of Purchased if applicable Order Number ready Warranty Extend Your Warranty by 1 Year Customer Support There are our general terms for the warranty service but we always encourage our customers to contact us if any issues regardless of warranty terms If...

Страница 20: ...We are expecting to see our products fulfill your life and hear your voice Your satisfaction means a lot to us Please tag us if you share a snap on your social media ...

Отзывы: