Setting the display range (function group RANGE)
5 Operation
USM Go
Rev. 10 (06/2021)
5-11
RANGE
You can use the function
RANGE
to set the range (the
display range) for making measurements.
You can set the display range by coarse adjustment
steps or by fine adjustment (see Section
The adjustment range is 0.5 … 20000.00 mm.
Note
The adjustment range for display range de-
pends on the sound velocity setting and on
the frequency range setting (function
FRE-
QUENCY
in the function group
RECEIVER
).
– Select the function
RANGE
.
– Set the required display range by means of the func-
tion keys or using the navigation.
– Press the two function keys at the same time to quick-
ly adjust an average value (254.00 mm).
PROBE DELAY
Every probe is equipped with a delay line between the
transducer and the coupling face. The sound pulse must
first pass through this delay line before it can enter the
test object. You can compensate for this influence of the
delay line in the probe in the function
PROBE DELAY
.
You can set the probe delay by coarse adjustment steps
or by fine adjustment (see Section
The adjustment range is 0 … 1000.000 µs.
Note
If the value for the probe delay is not known,
please read Chapter 5.8
, page 5-29 to determine this value.
– Select the function
PROBE DELAY
.
– Set the probe delay by means of the function keys or
using the navigation.
– Press the two function keys at the same time to set
the value to zero.
Содержание Krautkramer USM Go
Страница 1: ...Krautkrämer USM Go USM Go Operating Manual Id No 49 155 Rev 10 06 2021 ...
Страница 5: ...USM Go Rev 10 06 2021 0 5 Second operating level ...
Страница 6: ...0 6 Rev 10 06 2021 USM Go Second operating level continued ...
Страница 10: ...0 10 Rev 10 06 2021 USM Go ...
Страница 20: ...0 10 Rev 10 06 2021 USM Go ...
Страница 21: ...USM Go Rev 10 06 2021 1 1 Introduction 1 ...
Страница 35: ...USM Go Rev 10 06 2021 2 1 Standard package and accessories 2 ...
Страница 41: ...USM Go Rev 10 06 2021 3 1 Initial start up 3 ...
Страница 53: ...USM Go Rev 10 06 2021 4 1 Principles of operation 4 ...
Страница 76: ...4 Principles of operation Saving the settings 4 24 Rev 10 06 2021 USM Go ...
Страница 77: ...USM Go Rev 10 06 2021 5 1 Operation 5 ...
Страница 210: ...5 Operation Evaluation according to the DGS method 5 134 Rev 10 06 2021 USM Go ...
Страница 211: ...USM Go Rev 10 06 2021 6 1 Documentation 6 ...
Страница 240: ...6 30 Rev 10 06 2021 USM Go ...
Страница 241: ...USM Go Rev 10 06 2021 7 1 Maintenance and care 7 ...
Страница 247: ...USM Go Rev 10 06 2021 8 1 Interfaces and Peripherals 8 ...
Страница 251: ...USM Go Rev 10 06 2021 9 1 Appendix 9 ...
Страница 266: ...9 16 Rev 10 06 2021 USM Go ...
Страница 267: ...USM Go Rev 10 06 2021 10 1 Specifications 10 ...
Страница 278: ...10 12 Rev 10 06 2021 USM Go ...
Страница 279: ...USM Go Rev 10 06 2021 11 1 Index 11 ...