Safety Information
Safety Recommendations
Follow Safety Instructions
Carefully read all safety messages in this manual and on your equipment safety decals. Follow recommended precautions and safe
operating practices.
Keep safety decals in good condition. Replace missing or damaged safety decals.
Decal Descriptions
This diagram shows the proper location of the safety decals as shipped from the factory. Replace damaged or missing decals. Make sure
the decals are easy to see at all times.
WARNING!
Interference with the oscillating spout while the
unit is operating, or manually directing the
oscillating spout, will cause damage to the gear
motor. Keep oscillating path clear of obstructions.
This warning decal is found on the top of
oscillating units only.
READ AND SAVE THESE INSTRUCTIONS!
• This is an electric device with moving components. There is the possibility of fire, electric shock, or injury to persons. Ensure all the
safety recommendations are adhered to in order to minimize this risk.
• Disconnect all power and unplug the unit before you inspect, clean or perform maintenance on the components of the unit.
• Never reach into the unit when it is running; you could become entrapped by the v-belt or injured by the rotating fan blades.
• The metal frame edges are sharp; don't run your hand along them. Be careful and wear gloves when you reach under the frame to
inspect the PVC pipes and mesh socks.
• A GFCI (Ground Fault Circuit Interrupter) is recommended for use with this product.
• If pads and grates are removed for servicing, they must be replaced prior to operating unit.
3
Start Unit
-Turn Water pump on 5-10 minutes
before running blower. To wet evaporative cooling
pads.
Shut Down
-Turn Pump off and run only blower until
evaporative cooling pads are dry. This prolongs the
life of the pads.
WARRANTY- VOID IF YOU RUN THE PUMP
WITHOUT WATER.
CAUTION - ALWAYS TURN OFF AT SWITCH AND
DISCONNECT POWER BEFORE REMOVING
EVAPORATIVE COOLING PADS FOR CLEANING
OR INTERNAL MAINTENANCE.
CLEANING
- Clean pads a minimum of once every
two weeks. Remove pads from unit and clean with
garden hose only - DO NOT use chemicals or high
pressure hose.