ELECTRICAL SAFETY
• Turn OFF the power supply before connecting the device.
• Unconnected wires must be cut at different lengths and insulated singularly.
• Do not stretch the cable. Do not pull or carry by cable. Do not use the cable as a handle.
• In compliance with 2004/108/EC norm on electromagnetic compatibility, following precautions
must be taken:
• Before handling and installing the equipment, discharge electrostatic charges from your body
and tools which may come in touch with the device.
• Power supply must be stabilized without electronic noise. Install EMC filters on device power
supply if needed.
• Always use shielded cables (twisted pair cables whenever possible) and avoid cables longer
than necessary.
• Avoid placing the signal cable near high voltage power cables.
• Mount the device as far as possible from any capacitive or inductive noise source. Shield the
device from electronic noise source if needed.
• To guarantee a correct working of the device, avoid using strong magnets on or near by the
unit.
• Minimize electronic noise by connecting the cable shield and/or the connector housing and/or
the sensor to ground. Make sure that ground is not affected by electronic noise.
ELECTRICAL CONNECTION
Signals 0...20 mA
Signals 0...10 V
cable output connector output
0 VDC Power Supply
BK
1
13...30 VDC
RD
2
0 VDC analog
YE
3
START
BU
4
+I out
+V out
GN
5
STOP
OG
6
not connected
WH
7
FAULT
not connected
GY
8
Shielding
Shield
Case
Cable specifications
Type
HI-FLEX M8
Wires
2 x 0.22 mm
2
+ 6 x 0.14 mm
2
Shield
Tinned copper braid
External Ø
5.3 up to 5.6 mm
Impedance
<90 Ω/Km (0.22 mm
2
), <148 Ω/Km (0.14 mm
2
)
Min. bend radius ≥ 25 mm
1
2
5
4
3
7
6
8
connector output,
M12, male