DIAGNOSTIC LED
Diagnostic LED
ON
The sensor is running properly, there are no active errors
Blinking at high frequency
(100 ms ON / 100 ms OFF)
Machine data parameters error
Blinking slowly
(500 ms ON / 500 ms OFF)
Flash memory error
Blinking very slowly
(1 s ON / 1 s OFF)
Error of the sensors while reading the magnetic tape
Single flash
(200 ms ON / 1 s OFF)
The sensor is installed too far from the magnetic tape, the installation does not
comply with the tolerance values between the sensor and the tape
Double flash
(200 ms ON twice / 1 s OFF)
Several errors are active in the same time
Note:
When you execute the TEACH-IN, as soon as you activate the START input the LED switches off. As soon as you
activate the STOP input it switches on again.
DECLARATION OF EC-CONFORMITY
WayCon Positionsmesstechnik GmbH
Mehlbeerenstrasse
4
82024 Taufkirchen / Germany
This is to certify that the products
Classification
Magnetic scales
Series
MXAX and MXAZ
fulfill the current request of the following EC-directives:
EMV-directive
2014/30/EU
2011/65/EU
applied harmonized standards:
CEI EN 61000-6-4, CEI EN 61000-6-2
The declaration of conformity loses its validity if the product is misused or modified without proper
authorisation.
Taufkirchen,
02.10.2017
Andreas
Täger
CEO