Backhaul Unit Installation Instructions
This chapter describes how to install a backhaul unit with the WS-410.
Use the assembly equipment provided with the backhaul unit to install. Wavion does not
provide brackets or mounting equipment for the backhaul unit. Make sure the WS-410 is
installed in a higher position then the backhaul unit so the antennas are unobstructed. If the
backhaul unit is powered externally, connect to the Ethernet A port. If the backhaul unit is
not powered externally, connect to the Ethernet B port.
W
ARNING
:
Disconnect power to the WS-410 before connecting the backhaul
unit.
N
OTE
:
Make sure to use the correct Wavion part number for each backhaul
unit