Redundancy Controller
Page
32
Document Number: 90-005-0030_E
Power On
r108
1.
Verify that all cables, units, and waveguides are connected to the RMC.
1.
Turn on the computer where the Wavestream GUI is loaded and
open the GUI application by double-clicking the Wavestream icon.
2.
Turn on power to the RMC.
3.
Apply power to the SSPAs / BUCs.
4.
In the
Serial Ports
field on the GUI, select the appropriate com port; the only valid port for the
RMC is Ethernet.
5.
Press
Start
.
6.
Communication with the unit is established.
7.
The units are queried and status information is displayed for the primary unit.
8.
To view status for the backup / secondary unit press
Rackmount Thread
on the GUI toolbar
9.
Select
Thread A
to view SSPA-A or
Thread B
to view SSPA-B.
Select Power On Setting
To configure the power on setting:
Apply the software TX enable; note that this is not applicable in a redundancy
configuration.
Configure the power on setting in the GUI and save the default TX setting so that it will
be enabled at power up.