24

LDTC STATUS TAB

TC STATUS
Temperature Units: 

The indicator corresponding to the 

currently active temperature units will be lit.

Bias Current:

 There will be two indicators lit in this cluster, one 

indicates if bias current is auto ranging (AUTO) or manually 

fixed to a value (MAN). The bias current being applied to the 

sensor is also lit (10 µA, 100 µA, 1 mA, or 10 mA), indicating 

the bias current value.

IntelliTune Mode:

 One of the mode indicators will be lit, 

indicating the current IntelliTune mode setting.

LD STATUS
Laser Type & Control Mode: 

There will be two indicators lit 

in this cluster, one of either Laser Type A/B or Laser Type C, 

and one of either Constant Current (CC) or Constant Power 

(CP), indicating the laser type and operation mode currently 

active.

Photodiode Range:

 One of the indicators corresponding to 

the active photodiode range will be lit.

Figure 24.  LDTC Status Tab

Содержание LAB Series

Страница 1: ...bit RAM 256 MB minimum Screen Resolution 1024 x 768 pixels Disk Space 5 GB available hard disk space 32 bit 20 GB DirectX 9 graphics device with WDDM 1 0 or higher driver 64 bit Installation Prerequis...

Страница 2: ...s Virtual Instrument application the National Instrument NI Runtime Engine 2015 must be installed on the remote computer When installing the Virtual Instrument EXE file if the Runtime Engine is not a...

Страница 3: ...below the value specified Cable Resistance In the Cable Resistance control type the resistance of the cable in Ohms between the QCL LAB instrument and the load The QCL voltage displayed will be VDISPL...

Страница 4: ...can with decreasing current Step Duration sec In the Step Duration control type the time delay in seconds between each step in the VI scan The step size and duration determines the length of the scan...

Страница 5: ...logged Logged Data File Header In the Logged Data File Header control type the heading that appears at the top of a new data file If appending data the file header is not rewritten ADDITIONAL SETUP TA...

Страница 6: ...onal Instrument NI Runtime Engine 2015 must be installed on the remote computer When installing the Virtual Instrument EXE file if the Runtime Engine is not already installed on the computer a message...

Страница 7: ...rent Limit Power The Power button functions the same as the front panel power switch on the instrument Enable The Enable button enables current to the load and functions the same as the Enable button...

Страница 8: ...ain lit until the scan is complete Clicking the button again after starting IntelliTune will not stop the cycle The IntelliTune Abort button must be used to stop a cycle in progress If IntelliTune doe...

Страница 9: ...ntrol will configure the bias current for the auxiliary sensor Choose Auto to allow the TC LAB auto range function to choose an appropriate bias current or select a suitable range that will produce a...

Страница 10: ...istance sensors T1 R1 T2 R2 T3 R3 need to be populated by the temperatures resistances for the first second and third temperature resistance pairs respectively For Temperature Voltage sensors T1 V1 T2...

Страница 11: ...remote temperature scan the temperature iterations are done within the VI and as such no data will be logged to a flash drive if inserted The data will be saved to the appropriate file directory as sp...

Страница 12: ...efore data can be logged Logged Data File Header In the Logged Data File Header control type the heading that appears at the top of a new data file If appending data the file header is not rewritten I...

Страница 13: ...output The signal will go to the level indicated when the Actual Temperature exceeds the temperature limits Options are High 5V and Low 0V The temperature limits are configured on the Settings Monito...

Страница 14: ...has been stopped previously Use it to re start the execution of the program This is located in the upper left corner of the window Running This icon will only appear when the program is currently runn...

Страница 15: ...nded by Temp Limit Min and Temp Limit Max InTolerance Thisbooleanindicatorislitwhenthetemperature is in tolerance as described by the Temp Tolerance and Temp Time Tolerance fields INTELLITUNE PARAMETE...

Страница 16: ...temperature limit here in units chosen by the Temperature Units dropdown Available range is 99 to 250 C This value must be less than Temperature Setpoint and Temp Limit Max Temp Limit Max Enter the h...

Страница 17: ...ed by the command LASer AMPS returning 1 true If the indicator is not lit the units are in mA This will affect Laser Setpoint Laser Current Laser Current Limit Laser Current Tolerance Start Current St...

Страница 18: ...it This indicator is lit if the laser driver is operating in a current limit condition Time Delay Prior to Enabling LD Current msec Sets the delay time in milliseconds between when the output on comma...

Страница 19: ...oefficients Callendar Van Dusen parameters or Slope Offset parameters that can be used to characterize the sensor Save Configured Sensor Press the SAVE button when the calibration parameters the Senso...

Страница 20: ...profile has been selected press RECALL to load the profile The application will write the values to the instrument pause and re initialize to ensure synchronization Save to Profile Choose to which pro...

Страница 21: ...Data Temperature Scan Plot This plot shows the collected data Data points are Actual Temperature white circular points and Setpoint Temperature blue square points TEMPERATURE SCAN Start Temperature I...

Страница 22: ...t when the Begin V I Scan button has been pressed but the instrument is waiting for Laser Current to reach stability at the start current The scan will abort if the current does not come in to toleran...

Страница 23: ...Temperature red Low Temperature Limit green High Temperature Limit blue Temperature is plotted in the units currently active on the instrument LASER This plot shows various laser control parameters a...

Страница 24: ...0 A 100 A 1 mA or 10 mA indicating the bias current value IntelliTune Mode One of the mode indicators will be lit indicating the current IntelliTune mode setting LD STATUS Laser Type Control Mode Ther...

Страница 25: ...any other custom application without the express written permission of Wavelength Electronics Inc The QCL TC LDTC LAB LabVIEW Interface applications and their components and modules may not be redistr...

Страница 26: ...ry to change the temperature in the TC LAB VI but the VI resets the value to a different temperature A Temperature Scan is in progress Either wait for the temperature scan to finish or abort the tempe...

Страница 27: ...Buyer End User or Third Party Reseller are expressly prohibited from reverse engineering decompiling or disassembling this product NOTICE The information contained in this document is subject to chang...

Отзывы: