6
CAUTION:
Do not measure AC voltages if a motor on the circuit is being switched ON or
OFF. Large voltage surges may occur that can damage the meter.
1.
Set the function switch to the
VAC/Hz/%
position.
2.
Insert the black test lead banana plug into the negative
COM
jack.
Insert red test lead banana plug into the positive
V
jack.
3.
Touch the black test probe tip to the neutral side of the circuit.
Touch the red test probe tip to the
“hot” side of the circuit.
4.
Read the voltage in the main display and the frequency in the right
auxiliary display
5.
Press the
MODE
button to indicate “
Hz
”.
6.
Read the frequency in the main display.
7.
Press the
MODE
button again to indicate “
%
”.
8.
Read the % of duty cycle in the main display.
9.
Press EXIT for 2 seconds into the function of AC+DC. Test DC and
AC TRUE Rms.
mV VOLTAGE MEASUREMENTS
CAUTION:
Do not measure mV voltages if a motor on the circuit is being switched ON or
OFF. Large voltage surges may occur that can damage the meter.
1.
Set the function switch to the mV position.
2.
Press the
MODE
button to indicate “
DC
”. Or ““
AC
”, or in AC range press
EXIT
for two
seconds and chose
”AC+DC”
3.
Insert the black test lead banana plug into the negative
COM
jack.
Insert the red test lead banana plug into the positive
V
jack.
4.
Touch the black test probe tip to the negative side of the circuit.
Touch the red test probe tip to the positive side of the circuit.
5.
Read the mV voltage in the main display.
Содержание 98
Страница 2: ...2...