①
Peel off the DC cable insulation sleeve for 7 mm.
Figure 5-30
7mm
②
Disassemble the connector in the accessory bag.
Figure 5-31
+
-
③
Insert the DC cable through the DC connector nut into the metal terminal and press the
terminal with a professional crimping plier (pull back the cable with some power to check if
the terminal is well connected to the cable).
Figure 5-32
④
Insert the positive and negative cables into the corresponding positive and negative
connectors, pull back the DC cable to ensure that the terminal is tightly attached in the
connector.
⑤
Use an open-end wrench to screw the nut to the end to ensure that the terminal is well
sealed.