REPLAcING UV LAMP AND SERVIcING UV SYSTEM
NOTE: Avoid touching the sides of the quartz sleeve and lamp, handle by the ends only.
Step 1
Disconnect power.
Step 2
Turn water off and open valve down stream of system to relieve pressure.
Step 3
Remove vinyl cap and unscrew the nut.
Step 4
Carefully withdraw lamp approximately 2 inches from chamber.
Step 5
While holding lamp end carefully remove lamp socket on end now exposed.
Sept 6
Carefully withdraw lamp from chamber.
Step 7
Carefully remove O-ring from the end of quartz sleeve.
Step 8
Carefully remove quartz sleeve.
Step 9
To reinstall follow steps 8 through 1 in reverse.
MAINTENANcE SUGGESTION
To operate the sterilizer properly and attain its maximum efficiency it is recommended that the user performs the following maintenance:
1. Quartz sleeve cleaning or replacement:
a. Quartz sleeve is to be cleaned every 6 -12 months. Clean with glass cleaner.
b. Quartz sleeve is to be replaced every 24 months.
2. UV lamp replacement is recommended every 8000 - 9000 hours or operation (approx. 12 months of continuous service).
cAUTION:
Ultraviolet lamp and quartz sleeve are easily damaged. Pay attention when removing or replacing lamp and quartz sleeve!
ASSEMBLY
:
WARNING:
Germicidal ultraviolet rays are harmful to eyes and skin.
ITEM
DEScRIPTION
PART NUMBER
1
Ballast Assembly
WUVBALLAST2 (or 6, 8, 12) available in 110V or 230V
2
Germicidal Ultraviolet Lamp WUVLAMP2 (or 6, 8, 12)
3
Rubber O-Ring
T1200-0116
4
Quartz Sleeve
WUVQS2 (or 6,8,12)
5
Chamber
N/A
6
Mounting Clip
C2500W