Clearance equal to chamber length for lamp removal
SPEcIFIcATIONS
(Typical)
INSTALLATION:
Model
Flow Rate
(gpm)
Pipe Size
Dimensions (L x W x H)
Electrical
WUV2-110
2
1/2" MNPT
18 x 6 x 5 3/8"
110-130V / 50-60Hz
WUV2-230
2
1/2" MNPT
18 x 6 x 5 3/8
200-250V / 50-60Hz
WUV6-110
6
3/4" MNPT
25 1/2 x 6 x 5 3/8"
110-130V / 50-60Hz
WUV6-230
6
3/4" MNPT
25 1/2 x 6 x 5 3/8"
200-250V / 50-60Hz
WUV8-110
8
3/4" MNPT
32 x 8 1/4 x 3 3/4"
110-130V / 50-60Hz
WUV8-230
8
3/4" MNPT
32 x 8 1/4 x 3 3/4"
200-250V / 50-60Hz
WUV12-110
12
1" MNPT
4 1 1/2 x 8 1/4 x 3 3/4"
110-130V / 50-60Hz
WUV12-230
12
1" MNPT
4 1 1/2 x 8 1/4 x 3 3/4"
200-250V / 50-60Hz
NOTE:
Line cord and lamp lead wire omitted for clarity.
NOTES:
1. Install sterilizer equipment in a readily accessible and well lit location to facilitate inspection and maintenance.
2. Inspect for hidden electrical wiring or plumbing prior to drilling holes.
3. Attach mounting clips to the wall.
4. Insert chamber through mounting clips.
5. Connect to plumbing.
6. Install quartz sleeve and lamp.
Note: Avoid touching the sides of the quartz sleeve and lamp, handle by the ends only.
a. Remove the retainer nut.
b. Slide the quartz sleeve into the chamber - closed end first.
c. Side the O-ring over the open end of the quartz sleeve.
d. Tighten the retainer nut hand tight.
e. Slide the lamp into the quartz sleeve.
f. Connect the lamp to the plug in the transformer.
g. Cover the lamp connection with the vinyl cap
7. Turn on the water and inspect for leaks. Repair if necessary.
8a.
For 110 Volt Units:
Plug the transformer into an electrical outlet. An electrical outlet protected by a Ground Fault Interrupt (GFI)
circuit is recommended.
b.
For 220 Volt Units:
Obtain the appropriate plug for your type of receptacle and attach it to the end of the power cord and plug it in.
2